Performance characteristics of ejector expander transcritical CO2 refrigeration cycle

被引:29
作者
Ersoy, H. Kursad [1 ]
Bilir, Nagihan [1 ]
机构
[1] Selcuk Univ, Dept Mech Engn, Fac Engn & Architecture, TR-42250 Konya, Turkey
关键词
Suction nozzle; pressure drop; ejector; expansion; turbine; coefficient of performance; exergy; 2-PHASE EJECTOR; EXERGY;
D O I
10.1177/0957650912446547
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects on the performance of the basic CO2 refrigeration cycle when using an ejector as the expander to recover expansion work were investigated. A two-phase constant area ejector flow model was used in the ejector analysis. The coefficient of cooling performance and gas cooler pressure that yielded the maximum exergy efficiency, suction nozzle pressure drop, and optimum values for the ejector area ratio were determined for various evaporator and gas cooler outlet temperatures. Parametric studies were performed using engineering equation solver. The suction nozzle pressure drop had a significant effect on the ejector area ratio, coefficient of cooling performance, and exergy efficiency. It is necessary to design an ejector with the optimum area ratio to achieve the optimum pressure drop and maximum performance. Cycle that use the ejector as an expander always has higher coefficient of performance and exergy efficiency than conventional cycle under any operating condition. The irreversibility decreases compared to the classic refrigeration cycle when the ejector or turbine are used as an expander. The analysis results showed that - under a gas cooler pressure of 9.5 MPa, gas cooler outlet temperature of 40 degrees C, evaporator temperature of 5 degrees C, and cooling capacity of 3.5kW - the total irreversibility of the ejector system was lower than those of the basic and turbine expander systems by 39.1% and 5.46%, respectively.
引用
收藏
页码:623 / 635
页数:13
相关论文
共 26 条
  • [1] Performance improvement of the vapour compression refrigeration cycle by a two-phase constant area ejector
    Bilir, Nagihan
    Ersoy, H. Kursad
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) : 469 - 480
  • [2] Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    Chaiwongsa, Praitoon
    Wongwises, Somchai
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04): : 601 - 608
  • [3] Particular characteristics of transcritical CO2 refrigeration cycle with an ejector
    Deng, Jian-qiang
    Jiang, Pei-xue
    Lu, Tao
    Lu, Wei
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 381 - 388
  • [4] Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    Disawas, S
    Wongwises, S
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (06): : 587 - 594
  • [5] Elbel S., 2007, THESIS U ILLINOIS UR
  • [6] Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation
    Elbel, Stefan
    Hrnjak, Pega
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03): : 411 - 422
  • [7] The influence of ejector component efficiencies on performance of Ejector Expander Refrigeration Cycle and exergy analysis
    Ersoy, H. Kursad
    Bilir, Nagihan
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2010, 7 (04) : 425 - 438
  • [8] Klein SA, 2011, EES ENG EQUATION SOL
  • [9] Kohler J, 2009, INT REFR AIR COND C
  • [10] Kornhauser A.A., 1990, P 1990 USNC IIR PURD