Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes

被引:9
作者
de Oliveira-Roberth, Aline [1 ]
Santos, Diego I. V. [1 ]
Cordeiro, Diogo D. [1 ]
Lino, Fernando M. de A. [1 ]
Bara, Maria T. F. [1 ]
Gil, Eric de S. [1 ]
机构
[1] Univ Fed Goias, Fac Pharm, BR-74605220 Goiania, Go, Brazil
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2012年 / 10卷 / 05期
关键词
SPE; Disposable devices; Flavonoids; Voltammetry; Phytoteraphics; PASTE ELECTRODE;
D O I
10.2478/s11532-012-0093-3
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Rutin is a flavonoid commonly employed for many therapeutic purposes. Although the electroactive phenolic groups of rutin might be oxidized at low applied potential, the adsorption of oxidized species changes the electrode surface. As a consequence, the repeatability and reproducibility of the method decreases, which limits electroanalytical applications. This paper describes the use of disposable screen-printed electrodes as an alternative to improve the electrochemical quantification of rutin in commercial and standard samples. The electrochemical behavior was consistent to what is observed using other carbon electrodes: an adsorption-involved step and a pH-dependent oxidation process. The replacement of the electrodes between the analyses ensured rapid analysis, good intermediate precision and repeatability. The proposed method was successfully applied to rutin determination in pharmaceutical samples of capsules, with the limit of quantification being 0.30 A mu M.
引用
收藏
页码:1609 / 1616
页数:8
相关论文
共 23 条
[1]  
Association of Official Chemists, 1995, OFFICIAL METHODS ANA, P29
[2]   Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode [J].
Bergamini, Marcio F. ;
Santos, Andre L. ;
Stradiotto, Nelson R. ;
Zanoni, Maria Valnice B. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) :315-319
[3]   Electrochemical behavior of colchicine using graphite-based screen-printed electrodes [J].
Bodoki, E. ;
Laschi, Serena ;
Palchetti, Ilaria ;
Sandulescu, R. ;
Mascini, M. .
TALANTA, 2008, 76 (02) :288-294
[4]   Carbon nanotube disposable detectors in microchip capillary electrophoresis for water-soluble vitamin determination:: Analytical possibilities in pharmaceutical quality control [J].
Crevillen, Agustin G. ;
Pumera, Martin ;
Gonzalez, Maria Cristina ;
Escarpa, Alberto .
ELECTROPHORESIS, 2008, 29 (14) :2997-3004
[5]   Recent developments in the field of screen-printed electrodes and their related applications [J].
Dominguez Renedo, O. ;
Alonso-Lomillo, M. A. ;
Arcos Martinez, M. J. .
TALANTA, 2007, 73 (02) :202-219
[6]   Manufacture and evaluation of carbon nanotube modified screen-printed electrodes as electrochemical tools [J].
Fanjul-Bolado, Pablo ;
Queipo, Paula ;
Jose Lamas-Ardisana, Pedro ;
Costa-Garcia, Agustifn .
TALANTA, 2007, 74 (03) :427-433
[7]   Rutin determination in pharmaceutical formulations using a carbon paste electrode modified with poly(vinylpyrrolidone) [J].
Franzoi, Ana Cristina ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) :973-977
[8]   Biomimetic sensor based on MnIIIMnII complex as manganese peroxidase mimetic for determination of rutin [J].
Franzoi, Ana Cristina ;
Peralta, Rosely A. ;
Neves, Ademir ;
Vieira, Iolanda Cruz .
TALANTA, 2009, 78 (01) :221-226
[9]   Ultrasound applications in electrochemical systems: Theoretical and experimental aspects [J].
Garbellini, Gustavo S. ;
Salazar-Banda, Giancarlo R. ;
Avaca, Luis A. .
QUIMICA NOVA, 2008, 31 (01) :123-133
[10]   Electrochemical oxidation of rutin [J].
Ghica, ME ;
Brett, AMO .
ELECTROANALYSIS, 2005, 17 (04) :313-318