Clinical Application of a Novel Hybrid Intensity-Modulated Radiotherapy Technique for Stage III Lung Cancer and Dosimetric Comparison With Four Other Techniques

被引:41
|
作者
Verbakel, Wilko F. A. R. [1 ]
van Reij, Ellen [1 ]
Ladenius-Lischer, Ilonka [1 ]
Cuijpers, Johan P. [1 ]
Slotman, Ben J. [1 ]
Senan, Suresh [1 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Radiat Oncol, NL-1081 HV Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 83卷 / 02期
关键词
Stage III lung cancer; IMRT; RapidArc; Treatment planning comparison; 3-DIMENSIONAL CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; CONCURRENT CHEMOTHERAPY; PNEUMONITIS; DELIVERY; RAPIDARC; NSCLC;
D O I
10.1016/j.ijrobp.2011.12.059
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In large stage III lung tumors, planning delivery of doses exceeding 60 Gy can be challenging and time consuming. Intensity modulated radiation therapy (IMRT) can improve target coverage but may increase volumes receiving low-dose irradiation. We clinically implemented a novel hybrid IMRT (h-IMRT) technique that allowed plans to be produced quickly, and compared these plans with 4 other techniques. Methods and Materials: h-IMRT was used to treat 14 consecutive patients with planning target volumes (PTVs) exceeding 500 cm(3) (average, 779 cm(3)) with concurrent chemo-radiation therapy to 66 Gy. h-IMRT plans consisted of 2 components: an anterior-posterior/posterior-anterior/posterior-anterior (AP-PA-PA) oblique, open-field technique delivering an average dose of 58 Gy, plus a 3-field IMRT component optimized to achieve a final homogeneous dose of 66 Gy. Total lung V-20 and contralateral lung V-5 were kept as low as possible but preferably less than 35% and less than 50%, respectively. All plans were retrospectively replanned using a 5- to 9-field 3-dimensional conformal technique, full RapidArc, 6-field full IMRT, and a hybrid RapidArc (h-RapidArc) technique similar to the h-IMRT. Results: The h-IMRT, h-RapidArc, and full RapidArc plans could be generated in less than 2 h, with the first 2 plans achieving the lowest V-5 (36%) and V-20 (30%) values together with the smallest hot spots. Both the 3-dimensional conformal and full IMRT plans occasionally led to unacceptable hot spots outside the PTV. Full RapidArc plans were fast and achieved comparable V-20 values but led to slightly higher V-5 values. Conclusions: Both h-IMRT and h-RapidArc permitted delivery of 66 Gy to large stage III lung tumors, and both were superior to either full IMRT or RapidArc plans for reducing lung doses. The clinical significance of small increases in V-5 during chemo-radiation therapy delivery are unknown, but the present study suggests that h-IMRT and h-RapidArc are preferable for treatment of large tumors. (C) 2012 Elsevier Inc.
引用
收藏
页码:E297 / E303
页数:7
相关论文
共 50 条
  • [1] Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer
    Lu, Jia-Yang
    Lin, Zhu
    Zheng, Jing
    Lin, Pei-Xian
    Cheung, Michael Lok-Man
    Huang, Bao-Tian
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [3] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Ercan, Tuelay
    Igdem, Sefik
    Alco, Guel
    Zengin, Funda
    Atilla, Selin
    Dincer, Maktav
    Okkan, Sait
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04) : 283 - 289
  • [4] DOSIMETRIC BENEFITS OF A NOVEL INTENSITY MODULATED RADIOTHERAPY (IMRT) TECHNIQUE FOR TREATING LARGE VOLUME STAGE III LUNG CANCER
    Verbakel, Wilko F. A. R.
    Van Reij, Ellen
    Ladenius-Lischer, Lonka
    Slotman, Ben
    Senan, Suresh
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S795 - S795
  • [5] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Funda Zengin
    Selin Atilla
    Maktav Dinçer
    Sait Okkan
    Japanese Journal of Radiology, 2010, 28 : 283 - 289
  • [6] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy with Hybrid Intensity-Modulated Radiotherapy Techniques for Treatment of Locally Advanced Lung Cancer
    Suyunmez, Ozge
    Genc, Mine
    Ciftlikli, Ozlem Toykan
    Tuncel, Nina
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (03): : 239 - 245
  • [7] Radiotherapy for Esophageal Cancer Using Simultaneous Integrated Boost Techniques: Dosimetric Comparison of Helical TomoTherapy, Volumetric-modulated Arc Therapy (RapidArc) and Dynamic Intensity-Modulated Radiotherapy
    Wang, Yao-Ching
    Chen, Shang-Wen
    Chien, Chun-Ru
    Hsieh, Te-Chun
    Yu, Chun-Yen
    Kuo, Yu-Cheng
    Yang, Shih-Neng
    Kao, Chia-Hung
    Liang, Ji-An
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 485 - 491
  • [8] Dosimetric comparison of four radiotherapy techniques for stage III non-small cell lung cancer
    Li, Chao
    Luo, Haifeng
    Song, Wenli
    Hu, Yan
    Li, Jingjing
    Cai, Zhiqiang
    ONCOLOGY LETTERS, 2023, 26 (02)
  • [9] Adjuvant radiotherapy for gallbladder cancer: A dosimetric comparison of conformal radiotherapy and intensity-modulated radiotherapy
    Sun, Xiao-Nan
    Wang, Qi
    Gu, Ben-Xing
    Zhu, Yan-Hong
    Hu, Jian-Bin
    Shi, Guo-Zhi
    Zheng, Shu
    WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (03) : 397 - 402
  • [10] Comparison of combinations of irradiation techniques and jaw conditions in intensity-modulated radiotherapy for lung cancer
    Peng, Qinghe
    Shi, Junyue
    Zhang, Jun
    Li, Qiwen
    Li, Zhenghuan
    Zhang, Qingyuan
    Peng, Yinglin
    Chen, Li
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (10): : 178 - 189