Effect of pulse tube volume on dynamics of linear compressor and cooling performance in Stirling-type pulse tube refrigerator

被引:7
作者
Ko, Junseok [1 ]
Jeong, Sangkwon [2 ]
Ki, Taekyoung [2 ]
机构
[1] Korea Inst Machinery & Mat, Energy Plant Res Div, Taejon 305343, South Korea
[2] Korea Adv Inst Sci & Technol, Cryogen Engn Lab, Dept Mech Engn, Taejon 305701, South Korea
关键词
Pulse tube refrigerator; Linear compressor; Dynamics; MODEL;
D O I
10.1016/j.cryogenics.2009.08.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a Stirling-type pulse tube refrigerator (PTR), the Pulse tube volume affects the dynamic behavior of a linear compressor as well as the cooling performance of PTR. In this study, FTRs which have different pulse tube volume are tested and simulated. The simulation code is verified with the experimental measurement of piston displacement, pressure wave, input power and cooling capacity. And then, the power transfer from the electric power input to the cooling capacity is explained with the simulation results. The smaller pulse tube increases the resonant frequency of a linear compressor and suppresses the piston motion because it imposes larger gas spring effect and also larger gas damping effect to the piston. The smaller one allows larger power transfer from electric power to expansion PV work despite the smaller piston displacement, but shows less cooling capacity due to larger thermal losses. (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [31] Performance analysis and optimization of high capacity pulse tube refrigerator
    Ghahremani, Amir R.
    Saidi, M. H.
    Jahanbakhshi, R.
    Roshanghalb, F.
    CRYOGENICS, 2011, 51 (04) : 173 - 179
  • [32] Experimental investigation of pulse tube refrigerator with rod type displacer as phase shifter
    Wang, Mingjun
    Xu, Haojie
    Lin, Yuzhe
    Zhang, Zhao
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 93 : 47 - 51
  • [33] Lifetime prediction and reliability estimation methodology for Stirling-type pulse tube refrigerators by gaseous contamination accelerated degradation testing
    Wan, Fubin
    Tan, Yuanyuan
    Jiang, Zhenhua
    Chen, Xun
    Wu, Yinong
    Zhao, Peng
    CRYOGENICS, 2017, 88 : 116 - 124
  • [34] Pulse tube refrigerator based cryogenic cooling circuit for NMR cold probes
    Atrey, M. D.
    Healey, A.
    Janaway, T.
    McMahon, A.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 41 - +
  • [35] Energy distribution between liquid hydrogen and liquid oxygen temperatures in a Stirling/pulse tube refrigerator
    Ying, Kongkuai
    Yin, Wang
    Wu, Yinong
    Jiang, Zhenhua
    Song, Jiantang
    Liu, Shaoshuai
    Zhu, Haifeng
    FRONTIERS IN ENERGY, 2023, 17 (04) : 516 - 526
  • [36] Experimental results on V-M type pulse tube refrigerator
    Dai, W
    Matsubara, Y
    Kobayashi, H
    CRYOGENICS, 2002, 42 (6-7) : 433 - 437
  • [37] Development of a linear compressor for two-stage pulse tube cryocoolers
    Peng-da Yan
    Wei-li Gao
    Guo-bang Chen
    Journal of Zhejiang University-SCIENCE A, 2009, 10 : 1595 - 1600
  • [38] Analytical study of the performance of pulse tube refrigerator with symmetry-nozzle
    Yang, LW
    Zhou, YA
    Liang, JT
    Zhu, WX
    CRYOGENICS, 1999, 39 (09) : 723 - 727
  • [39] An 80 mW/8 K high-frequency pulse tube refrigerator driven by only one linear compressor
    Wu, Xianlin
    Chen, Liubiao
    Li, Xuming
    Wang, Jue
    Zhou, Yuan
    Wang, Junjie
    CRYOGENICS, 2019, 101 : 7 - 11
  • [40] Advances in single- and multi-stage Stirling-type pulse tube cryocoolers for space applications in NLIP/SITP/CAS
    Dang, Haizheng
    Tan, Jun
    Zha, Rui
    Li, Jiaqi
    Zhang, Lei
    Zhao, Yibo
    Gao, Zhiqian
    Bao, Dingli
    Li, Ning
    Zhang, Tao
    Zhao, Yongjiang
    Zhao, Bangjian
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278