Effect of pulse tube volume on dynamics of linear compressor and cooling performance in Stirling-type pulse tube refrigerator

被引:7
|
作者
Ko, Junseok [1 ]
Jeong, Sangkwon [2 ]
Ki, Taekyoung [2 ]
机构
[1] Korea Inst Machinery & Mat, Energy Plant Res Div, Taejon 305343, South Korea
[2] Korea Adv Inst Sci & Technol, Cryogen Engn Lab, Dept Mech Engn, Taejon 305701, South Korea
关键词
Pulse tube refrigerator; Linear compressor; Dynamics; MODEL;
D O I
10.1016/j.cryogenics.2009.08.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a Stirling-type pulse tube refrigerator (PTR), the Pulse tube volume affects the dynamic behavior of a linear compressor as well as the cooling performance of PTR. In this study, FTRs which have different pulse tube volume are tested and simulated. The simulation code is verified with the experimental measurement of piston displacement, pressure wave, input power and cooling capacity. And then, the power transfer from the electric power input to the cooling capacity is explained with the simulation results. The smaller pulse tube increases the resonant frequency of a linear compressor and suppresses the piston motion because it imposes larger gas spring effect and also larger gas damping effect to the piston. The smaller one allows larger power transfer from electric power to expansion PV work despite the smaller piston displacement, but shows less cooling capacity due to larger thermal losses. (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Analysis on the stirling-type pulse tube refrigerator in consideration of dynamics of linear compressor
    Ko, Junseok
    Jeong, Sangkwon
    CRYOGENICS, 2008, 48 (1-2) : 68 - 76
  • [2] Investigation on dynamic behavior of linear compressor in Stirling-type pulse tube refrigerator
    Ko, Junseok
    Jeong, Sangkwon
    Kim, Youngkwon
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1093 - 1099
  • [3] STIRLING-TYPE PULSE TUBE REFRIGERATOR (PTR) DRIVEN BY COLD LINEAR COMPRESSOR
    Park, Jiho
    Cha, Jeongmin
    Ko, Junseok
    Jeong, Sangkwon
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 697 - 704
  • [4] MEASUREMENT AND ANALYSIS OF ENERGY FLOW IN STIRLING-TYPE PULSE TUBE REFRIGERATOR
    Ki, T.
    Jeong, S.
    Seo, M.
    Park, I.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 555 - 562
  • [5] Stirling-type pulse tube refrigerator (PTR) with cold compression: Cold compressor, colder expander
    Park, Jiho
    Ko, Junseok
    Cha, Jeongmin
    Jeong, Sangkwon
    CRYOGENICS, 2016, 74 : 66 - 72
  • [6] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    THUMMES Günter
    ChineseScienceBulletin, 2005, (16) : 144 - 146
  • [7] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    Tang, K
    Chen, GB
    Thummes, G
    CHINESE SCIENCE BULLETIN, 2005, 50 (16): : 1814 - 1816
  • [8] Movement of linear compressor and displacer in a displacer pulse tube refrigerator
    Zhu, Shaowei
    CRYOGENICS, 2019, 97 : 70 - 76
  • [9] Real-time measurement and analysis of energy flow in Stirling-type pulse tube refrigerator
    Ki, Taekyung
    Jeong, Sangkwon
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 90 : 1 - 8
  • [10] Development and experimental investigation of Stirling-type pulse tube refrigerator (PTR) below 20 K; cold compressor and colder expander
    Park, Jiho
    Jeong, Sangkwon
    Cha, Jeongmin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 : 64 - 76