Enzyme electrodes based on sono-gel containing ferrocenyl compounds

被引:23
作者
Ballarin, Barbara [1 ]
Cassani, Maria Cristina [1 ]
Mazzoni, Rita [1 ]
Scavetta, Erika [1 ]
Tonelli, Domenica [1 ]
机构
[1] Univ Bologna, Dipartimento Chim Fis & Inorgan, I-40136 Bologna, Italy
关键词
ferrocene; 1,2-diferrocenylethane; sono-gel; composite electrode; biosensor; glucose oxidase;
D O I
10.1016/j.bios.2006.05.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amperometric-mediated glucose sensor has been developed by employing a silica sono-gel carbon composite electrode (SCC). The chosen mediators, ferrocene (Fc) and 1,2-diferrocenylethane (1), have been immobilized in the sono-gel composite matrix. The complex 1 has been employed for the first time as an electron transfer mediator for signal transduction from the active centre of the enzyme to the electrode conductive surface. After the optimisation of the construction procedure the best operative conditions for the analytical performance of the biosensor have been investigated in terms of pH, temperature and applied potential. Cyclic voltarnmetric and amperometric measurements have been used to study the response of both the glucose sensors, which exhibit a fast response and good reproducibility. The sensitivity to glucose is quite similar (6.7 +/- 0.1 mu A/mM versus 5.3 +/- 0.1 mu A/mM) when either Fe or 1 are used as mediators as are the detection limit ca. 1.0 mM (S/N = 3) and the range of linear response (up to 13.0 mM). However, the dynamic range for glucose determination results wider when using 1 (up to 25.0 mM). The apparent Michaelis-Menten constants, calculated from the reciprocal plot under steady state conditions, are 27.7 and 31.6 mM for SCC-Fc/GOx and SCC-1/GOx electrodes, respectively, in agreement with a slightly higher electrocatalytic efficiency for the mediator 1. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1317 / 1322
页数:6
相关论文
共 32 条
  • [1] THE DESIGN OF ENZYME SENSORS BASED ON THE ENZYME STRUCTURE
    ALVAREZICAZA, M
    KALISZ, HM
    HECHT, HJ
    AUMANN, KD
    SCHOMBURG, D
    SCHMID, RD
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (08) : 735 - 742
  • [2] New rigid conducting composites for electrochemical sensors
    Ballarin, B
    Cordero-Rando, MD
    Blanco, E
    Hidalgo-Hidalgo De Cisneros, JL
    Seeber, R
    Tonelli, D
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2003, 68 (08) : 1420 - 1436
  • [3] TETRAFERROCENYLETHYLENE, A CHIRAL, ORGANOMETALLIC PROPELLER - SYNTHESIS, STRUCTURE, AND ELECTROCHEMISTRY
    BILDSTEIN, B
    DENIFL, P
    WURST, K
    ANDRE, M
    BAUMGARTEN, M
    FRIEDRICH, J
    ELLMERERMULLER, E
    [J]. ORGANOMETALLICS, 1995, 14 (09) : 4334 - 4342
  • [4] BINKER CJ, 1989, SOL GEL SCI PHYS CHE
  • [5] Blanco E, 1999, APPL ORGANOMET CHEM, V13, P399, DOI 10.1002/(SICI)1099-0739(199905)13:5<399::AID-AOC825>3.0.CO
  • [6] 2-A
  • [7] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [8] Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane
    Chen, XH
    Hu, YB
    Wilson, GS
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) : 1005 - 1013
  • [9] The Sonogel-Carbon electrode as a sol-gel graphite-based electrode
    Cordero-Rando, MDM
    de Cisneros, JLHH
    Blanco, E
    Naranjo-Rodríguez, I
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (10) : 2423 - 2427
  • [10] THE ELECTROCHEMISTRY OF HEXACYANORUTHENATE AT CARBON ELECTRODES AND THE USE OF RUTHENIUM COMPOUNDS AS MEDIATORS IN THE GLUCOSE GLUCOSE-OXIDASE SYSTEM
    CRUMBLISS, AL
    HILL, HAO
    PAGE, DJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 206 (1-2): : 327 - 331