Permanent corrosion monitoring in new and existing reinforced concrete structures

被引:0
|
作者
Broomfield, JP [1 ]
Davies, K [1 ]
Hladky, K [1 ]
机构
[1] BGB Projects Ltd, Manchester M41 5PT, Lancs, England
关键词
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Corrosion-monitoring systems consisting of linear polarization, concrete resistivity, and other probes have been installed in new structures to monitor durability and in existing structures to evaluate rehabilitation strategies such as corrosion inhibitor application and patch repairs. The types of sensors used, data collection techniques, results, and interpretation are discussed.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [1] The use of permanent corrosion monitoring in new and existing reinforced concrete structures
    Broomfield, JP
    Kevin, DB
    Hladky, K
    CEMENT & CONCRETE COMPOSITES, 2002, 24 (01): : 27 - 34
  • [2] Embedded Sensors for Corrosion Monitoring of Existing Reinforced Concrete Structures
    Pereira, E. V.
    Figueira, R. B.
    Salta, M. M.
    Fonseca, I. T. E.
    ADVANCED MATERIALS FORUM IV, 2008, 587-588 : 677 - +
  • [3] CORROSION MONITORING IN REINFORCED CONCRETE STRUCTURES
    Nygaard, Peter V.
    Klinghoffer, Oskar
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 1219 - 1228
  • [4] Monitoring corrosion in reinforced concrete structures
    Kung, Peter
    Comanici, Maria I.
    SENSORS FOR EXTREME HARSH ENVIRONMENTS, 2014, 9113
  • [5] Corrosion Monitoring in Reinforced Concrete - Structures New Research Results
    Fraundorfer, Andreas
    Dauberschmidt, Christoph
    BETON- UND STAHLBETONBAU, 2022, 117 (12) : 956 - 967
  • [6] Corrosion inhibition of nitrite in existing reinforced concrete structures
    Liu, Jing
    Yan, Jiali
    Dai, Yanhua
    Li, Yushun
    ADVANCES IN ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2016, : 677 - 680
  • [7] Corrosion monitoring of reinforced concrete structures - A review
    Song, Ha-Won
    Saraswathy, Velu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 1 - 28
  • [8] Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures
    Duffo, Gustavo S.
    Farina, Silvia B.
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (08) : 2746 - 2751
  • [9] Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures
    Verma, Sanjeev Kumar
    Bhadauria, Sudhir Singh
    Akhtar, Saleem
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [10] Proposal of method monitoring macrocell corrosion rate at existing reinforced concrete
    Hiraishi, Yoichi
    Miyazato, Shinichi
    Umino, Norihiko
    Fujimoto, Kazuo
    Zairyo/Journal of the Society of Materials Science, Japan, 2008, 57 (05) : 502 - 508