Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

被引:6
|
作者
Walton, Courtney L. [1 ]
Kertesz, Vilmos [1 ]
Cahill, John F. [1 ]
机构
[1] Oak Ridge Natl Lab, POB 2009, Oak Ridge, TN 37831 USA
关键词
hand-held; open-port sampling interface; liquid extraction; tethered; ELECTROSPRAY-IONIZATION; PROBE; PESTICIDES; DEMAND; TOOL;
D O I
10.1021/jasms.0c00268
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Presented is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves. [Graphics]
引用
收藏
页码:198 / 205
页数:8
相关论文
共 50 条
  • [1] Immediate drop on demand technology (I-DOT) coupled with mass spectrometry via an open port sampling interface
    Van Berkel, Gary J.
    Kertesz, Vilmos
    Boeltz, Harry
    BIOANALYSIS, 2017, 9 (21) : 1667 - 1679
  • [2] Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry
    Van Berkel, Gary J.
    Kertesz, Vilmos
    Orcutt, Matt
    Bentley, Adam
    Glick, Jim
    Flarakos, Jimmy
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12578 - 12586
  • [3] Fluid Dynamics of the Open Port Interface for High-Speed Nanoliter Volume Sampling Mass Spectrometry
    Liu, Chang
    Van Berkel, Gary J.
    Kovarik, Peter
    Perot, J. Blair
    Inguva, Venkatesh
    Covey, Thomas R.
    ANALYTICAL CHEMISTRY, 2021, 93 (24) : 8559 - 8567
  • [4] Open port sampling interface mass spectrometry of wipe-based explosives, oxidizers, and narcotics for trace contraband detection
    Forbes, Thomas P.
    Lawrence, Jeffrey
    Hao, Changtong
    Gillen, Greg
    ANALYTICAL METHODS, 2021, 13 (31) : 3453 - 3460
  • [5] Application of open port sampling interface mass spectrometry (OPSI-MS) to deuterium exchange as an aid for structural elucidation
    Ray, Andrew D.
    Clemens, Graeme
    Holman, Stephen W.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35
  • [6] Detection of Opioids on Mail/Packages Using Open Port Interface Mass Spectrometry (OPI-MS)
    Metwally, Haidy
    Agrawal, Prashant
    Smith, Rachael
    Liu, Chang
    LeBlanc, Yves
    Covey, Thomas R.
    Oleschuk, Richard
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (11) : 2370 - 2378
  • [7] Direct sampling and analysis from solid-phase extraction cards using an automated liquid extraction surface analysis nanoelectrospray mass spectrometry system
    Walworth, Matthew J.
    ElNaggar, Mariam S.
    Stankovich, Joseph J.
    Witkowski, Chuck
    Norris, Jeremy L.
    Van Berkel, Gary J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (17) : 2389 - 2396
  • [8] Evaluation of a liquid electron ionization liquid chromatography-mass spectrometry interface
    Termopoli, Veronica
    Famiglini, Giorgio
    Palma, Pierangela
    Piergiovanni, Maurizio
    Rocio-Bautista, Priscilla
    Ottaviani, Maria Francesca
    Cappiello, Achille
    Saeed, Mansoor
    Perry, Simon
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1591 : 120 - 130
  • [9] Nanospray desorption electrospray ionization: an ambient method for liquid-extraction surface sampling in mass spectrometry
    Roach, Patrick J.
    Laskin, Julia
    Laskin, Alexander
    ANALYST, 2010, 135 (09) : 2233 - 2236
  • [10] Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles
    Swanson, Kenneth D.
    Worth, Anne L.
    Glish, Gary L.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (02) : 297 - 303