An abridged technique to diagnose spectrophotometric errors

被引:0
|
作者
Berns, RS
Reniff, L
机构
[1] Munsell Color Science Laboratory, Center for Imaging Science, Rochester Institute of Technology, Rochester, NY 14623-5604
关键词
measurement; spectrophotometry; spectrophotometric error; color-measurement instruments; reproducibility; accuracy; BCRA tiles;
D O I
10.1002/(SICI)1520-6378(199702)22:1<51::AID-COL8>3.0.CO;2-3
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The effect on colorimetric accuracy of spectrophotometric errors (+/- 0.5 and +/- 1% reference white, +/- 0.25 and +/- 0.5% reference black, and +/- 0.5 and +/- 1 nm wavelength) was simulated for the BCRA Sei-ies II tile set by using previously investigated models for these errors. Delta E(94)* color differences of up to 5.2 could result. Because the errors are linearly related to CIELAB differences for each tile, a technique was derived that enabled Delta L* Delta a*, and Delta b* coordinates between a calibrated tile and its measured value to be transformed into estimates of reference white, reference black, and wavelength error. The cyan tile was identified as the most effective tile for this technique. "Universal" equations are included for 45/Normal and Normal/Total geometries traceable to the National Institute of Standards and Technology (NIST), and Normal/45, Normal/Total, and Normal/Diffuse geometries traceable to the National Physical Laboratory (NPL). Measuring the cyan tile on a regular basis and transforming its colorimetric coordinates into spectrophotometric error metrics provides a useful method to validate the accuracy and reproducibility of a color-measurement instrument. (C) 1997 John Wiley & Sons, Inc.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 41 条
  • [1] Assessment of pH dependent errors in spectrophotometric pH measurements of seawater
    Takeshita, Yuichiro
    Johnson, Kenneth S.
    Coletti, Luke J.
    Jannasch, Hans W.
    Walz, Peter M.
    Warren, Joseph K.
    MARINE CHEMISTRY, 2020, 223 (223)
  • [2] Quantitative spectrophotometric estimation of cefadroxil using hydrotropic solubilization technique
    Shukla, Ravi S.
    Patel, Asha
    Soni, M. L.
    Modi, Vishesh
    Jaliwala, Y. A.
    ASIAN JOURNAL OF PHARMACEUTICS, 2008, 2 (03) : 146 - 147
  • [3] Validated spectrophotometric estimation of esomeprazole using hydrotrophic solubilisation technique
    Magesh, A. R.
    Vijayalakshmi, R.
    Satyavati, D.
    Devi, G. Sravanthi
    Dhanaraju, M. D.
    ORIENTAL JOURNAL OF CHEMISTRY, 2010, 26 (03) : 1191 - 1193
  • [4] Quantitative spectrophotometric estimation of famotidine using hydrotropic solubilization technique
    Maheshwari, R. K.
    Shukla, Ravi Shankar
    ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (06) : 4221 - 4224
  • [5] A simple spectrophotometric technique for determination of Irganox 1010 in polymeric samples
    Farajzadeh, Mir Ali
    Nasserzadeh, Akram
    Ranji, Ali
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 157 - 162
  • [6] Spectrophotometric analysis of amoxycillin in tablets using hydrotropic solubilization technique
    Maheshwari, R. K.
    ASIAN JOURNAL OF CHEMISTRY, 2006, 18 (04) : 3194 - 3196
  • [7] A SENSITIVE SPECTROPHOTOMETRIC TECHNIQUE FOR MEASURING PHOTOTAXIS IN CHLAMYDOMONAS-REINHARDTII
    MOYER, RC
    SCHROEDER, WF
    TABOADA, J
    TEXAS JOURNAL OF SCIENCE, 1993, 45 (01): : 19 - 28
  • [8] Highly Sensitive and Validated Spectrophotometric Technique for the Assay of Some Antidepressant Drugs
    H. N. Deepakumari
    M. K. Prashanth
    B. C. Vasantha Kumar
    H. D. Revanasiddappa
    Journal of Applied Spectroscopy, 2015, 81 : 1004 - 1011
  • [9] Spectrophotometric determination of trace germanium in Chinese medicine by hydride generation technique
    Qiu, PH
    Zhang, HJ
    Xie, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (05) : 577 - 579
  • [10] Highly Sensitive and Validated Spectrophotometric Technique for the Assay of Some Antidepressant Drugs
    Deepakumari, H. N.
    Prashanth, M. K.
    Kumar, B. C. Vasantha
    Revanasiddappa, H. D.
    JOURNAL OF APPLIED SPECTROSCOPY, 2015, 81 (06) : 1004 - 1011