Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design

被引:90
作者
Cook, SD [1 ]
Salkeld, SL [1 ]
Whitecloud, TS [1 ]
Barbera, J [1 ]
机构
[1] Tulane Univ, Sch Med, Dept Orthopaed Surg, New Orleans, LA 70112 USA
来源
JOURNAL OF SPINAL DISORDERS | 2000年 / 13卷 / 03期
关键词
biomechanical testing; pedicle screws; osteoporotic bone; revision surgery; clinical study;
D O I
10.1097/00002517-200006000-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The advantages of pedicle screw fixation depend on their ability to retain bony purchase until the fusion mass is stable. Osteoporotic bone and removal and replacement of pedicle screws in revision procedures substantially reduce screw mechanical fixation strength and can lead to clinical failure. The objective of this study was to determine if an expansive pedicle screw design could be used to improve biomechanical fixation in bone of compromised quality. Axial mechanical pullout testing was performed on paired expansive and conventional pedicle screws placed in fresh, unembalmed cadaveric vertebrae. Bone mineral density measurements (made using a dual-energy X-ray absorption meter) were used to characterize bone quality. A preliminary clinical and radiographic evaluation of 14 patients was also performed at a minimum 2-year follow-up. The mean axial pullout force in bone of all qualities was increased 30% when the expansive pedicle screw design was used. This included an appropriate 50% increase in pullout force in bone of poor quality (low bone mineral density). The preliminary clinical and radiographic results were supportive of the biomechanical design rationale and mechanical testing. The results were similar to those expected for spinal instrumentation using pedicle screws, even though compromised bone was present in two thirds of the cases in which the expansive screw was used.
引用
收藏
页码:230 / 236
页数:7
相关论文
共 23 条
  • [1] COE JD, 1997, SPINE, V9, P902
  • [2] STATIC AND CYCLICAL BIOMECHANICAL ANALYSIS OF PEDICLE SCREW SPINAL CONSTRUCTS
    CUNNINGHAM, BW
    SEFTER, JC
    SHONO, Y
    MCAFEE, PC
    [J]. SPINE, 1993, 18 (12) : 1677 - 1688
  • [3] BIOMECHANICAL ANALYSIS OF ANTERIOR AND POSTERIOR INSTRUMENTATION SYSTEMS AFTER CORPECTOMY - A CALF-SPINE MODEL
    GURR, KR
    MCAFEE, PC
    SHIH, CM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (08) : 1182 - 1192
  • [4] EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION
    HALVORSON, TL
    KELLEY, LA
    THOMAS, KA
    WHITECLOUD, TS
    COOK, SD
    [J]. SPINE, 1994, 19 (21) : 2415 - 2420
  • [5] KLEEMAN BC, 1987, P SOC BIOM ANN M NEW
  • [6] KORANYI E, 1970, CLIN ORTHOP RELAT R, P283
  • [7] A COMPARISON OF SINGLE-LEVEL FUSIONS WITH AND WITHOUT HARDWARE
    LORENZ, M
    ZINDRICK, M
    SCHWAEGLER, P
    VRBOS, L
    COLLATZ, MA
    BEHAL, R
    CRAM, R
    [J]. SPINE, 1991, 16 (08) : S455 - S458
  • [8] MCLAIN RF, 1995, J SPINAL DISORD, V8, P62
  • [9] TRANSPEDICULAR SCREW FIXATION
    MORAN, JM
    BERG, WS
    BERRY, JL
    GEIGER, JM
    STEFFEE, AD
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (01) : 107 - 114
  • [10] NUNAMAKER DM, 1976, J BIOMECH, V203, P54