Noninvasive methods for bilirubin measurements in newborns: A report

被引:5
作者
Okwundu, Charles, I [1 ]
Saini, Shiv Sajan [2 ]
机构
[1] Stellenbosch Univ, Fac Med & Hlth Sci, Ctr Evidence Based Hlth Care, Cape Town, South Africa
[2] Post Grad Inst Med Educ & Res, Dept Pediat, Div Neonatol, Chandigarh, India
关键词
Icterometry; Image Processing; Computer-Assisted; Kramer's rule; Mobile phone; Transcutaneous bilirubinometry; Visual assessment; TOTAL SERUM BILIRUBIN; TRANS-CUTANEOUS BILIRUBINOMETRY; TRANSCUTANEOUS BILIRUBINOMETRY; NEONATAL JAUNDICE; PRETERM INFANTS; CLINICAL-ASSESSMENT; SCREENING TOOL; TERM INFANTS; HYPERBILIRUBINEMIA; ACCURACY;
D O I
10.1016/j.semperi.2020.151355
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
New technologies have become available for noninvasive assessments of neonatal hyperbilirubinemia. Our objective is to review the noninvasive methods for measuring bilirubin in the newborn. We searched relevant literature from 1966 to January 1, 2020, which included cross-sectional studies to define the accuracy of any noninvasive methods for measuring or estimating total serum/plasma bilirubin (TB) levels in newborns. We identified and included 83 relevant studies of direct visual assessment, icterometry, mobile phone applications, and transcutaneous bilirubinometry (TcB). Compared with laboratory TB measurements, visual assessment was the least accurate and least reliable (r: 0.37 to 074), while TcB was the most accurate, but not always near-equivalent (r: 0.45 to 0.99). The sensitivity and specificity of TcB cut-off values to detect significant hyperbilirubinemia (TB>95th percentile for age in hours) ranged from 74% to 100% and 18% to 89%, respectively. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页数:31
相关论文
共 82 条
  • [1] Comparison between transcutaneous bilirubinometry and total serum bilirubin measurements in preterm infants <35 weeks gestation
    Ahmed, M.
    Mostafa, S.
    Fisher, G.
    Reynolds, T. M.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 72 - 77
  • [2] Validation of a transcutaneous bilirubin meter in Mongolian neonates: comparison with total serum bilirubin
    Akahira-Azuma, Moe
    Yonemoto, Naohiro
    Ganzorig, Battsengel
    Mori, Rintaro
    Hosokawa, Shinichi
    Matsushita, Takeji
    Bavuusuren, Bayasgalantai
    Shonkhuuz, Enkhtur
    [J]. BMC PEDIATRICS, 2013, 13
  • [3] Aprillia Z, 2017, COMPR CHILD ADOLES N, V40, P88, DOI 10.1080/24694193.2017.1386975
  • [4] Neonatal Jaundice Detection System
    Aydin, Mustafa
    Hardalac, Firat
    Ural, Berkan
    Karap, Serhat
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (07)
  • [5] Bhutani-based nomograms for the prediction of significant hyperbilirubinaemia using transcutaneous measurements of bilirubin
    Bental, Y. A.
    Shiff, Y.
    Dorsht, N.
    Litig, E.
    Tuval, L.
    Mimouni, F. B.
    [J]. ACTA PAEDIATRICA, 2009, 98 (12) : 1902 - 1908
  • [6] Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
    Bhutani, VK
    Gourley, GR
    Adler, S
    Kreamer, B
    Dalin, C
    Johnson, LH
    [J]. PEDIATRICS, 2000, 106 (02) : E17
  • [7] BHUTTA Z A, 1991, JPMA (Journal of the Pakistan Medical Association), V41, P155
  • [8] Transcutaneous measurement of hyperbilirubinaemia: comparison of the Minolta jaundice meter and the Ingram icterometer
    Bilgen, H
    Ince, Z
    Ozek, E
    Bekiroglu, N
    Ors, R
    [J]. ANNALS OF TROPICAL PAEDIATRICS, 1998, 18 (04): : 325 - 328
  • [9] Prediction of severe hyperbilirubinaemia using the Bilicheck transcutaneous bilirubinometer
    Boo, Nem-Yun
    Ishak, Shareena
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2007, 43 (04) : 306 - 311
  • [10] Transcutaneous bilirubin measurement at the time of hospital discharge in a multiethnic newborn population
    Campbell, Douglas M.
    Danayan, Karoon C.
    McGovern, Valleverdina
    Cheema, Sohail
    Stade, Brenda
    Sgro, Michael
    [J]. PAEDIATRICS & CHILD HEALTH, 2011, 16 (03) : 141 - 145