Validation of diffuse reflectance spectroscopy with magnetic resonance imaging for accurate vertebral bone fat fraction quantification

被引:6
作者
Swamy, Akash [1 ,2 ]
Burstrom, Gustav [3 ,4 ]
Spliethoff, Jarich W. [2 ]
Babic, Drazenko [2 ]
Ruschke, Stefan [5 ]
Racadio, John M. [6 ]
Edstrom, Erik [3 ,4 ]
Terander, Adrian Elmi [3 ,4 ]
Dankelman, Jenny [1 ]
Hendriks, Benno H. W. [1 ,2 ]
机构
[1] Delft Univ Technol, Dept Biomech Engn, Mekelweg 2, NL-2628 CD Delft, Netherlands
[2] Royal Philips NV, Philips Res, Dept In Body Syst, High Tech Campus 34, NL-5656 AE Eindhoven, Netherlands
[3] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[4] Karolinska Univ Hosp, Dept Neurosurg, S-17176 Stockholm, Sweden
[5] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiol, Ismaninger Str 22, D-81675 Munich, Germany
[6] Cincinnati Childrens Hosp Med Ctr, 3333 Burnet Ave, Cincinnati, OH 45229 USA
关键词
LUMBAR INTERBODY FUSION; PEDICLE SCREW INSERTION; MARROW FAT; MR SPECTROSCOPY; OPTICAL SPECTROSCOPY; SPINAL-FUSION; OPEN SURGERY; DENSITY; WATER; TISSUE;
D O I
10.1364/BOE.10.004316
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Safe and accurate placement of pedicle screws remains a critical step in open and minimally invasive spine surgery. The diffuse reflectance spectroscopy (DRS) technique may offer the possibility of intra-operative guidance for pedicle screw placement. Currently, Magnetic Resonance Imaging (MRI) is one of the most accurate techniques used to measure fat concentration in tissues. Therefore, the purpose of this study is to compare the accuracy of fat content measured invasively in vertebrae using DRS and validate it against the Proton density fat fraction (PDFF) derived via MRI. Chemical shift-encoding-based water-fat imaging of the spine was first performed on six cadavers. PDFF images were computed and manually segmented. 23 insertions using a custom-made screw probe with integrated optical fibers were then performed under cone beam computer tomography (CBCT). DR spectra were recorded at several positions along the trajectory as the optical screw probe was inserted turn by turn into the vertebral body. Fat fractions determined via DRS and MRI techniques were compared by spatially correlating the optical screw probe position within the vertebrae on CBCT images with respect to the PDFF images. The fat fraction determined by DRS was found to have a high correlation with those determined by MRI. with a Pearson coefficient of 0.950 (P<0.001) as compared with PDFF measurements calculated from the MR1 technique. Additionally, the two techniques were found to be comparable for fat fraction quantification within vertebral bodies (R-2 = 0.905). (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:4316 / 4328
页数:13
相关论文
共 40 条
  • [31] The Liver Fat Fraction and Abdominal Subcutaneous and Visceral Fat Volume Distribution in Normal-Weight, Overweight, and Obese Children Using a New Magnetic Resonance Imaging Technique
    Pirimoglu, Berhan
    Sade, Recep
    Islek, Ali
    Kantarci, Mecit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 194 - 199
  • [32] Validation of diffuse correlation spectroscopic measurement of cerebral blood flow using phase-encoded velocity mapping magnetic resonance imaging
    Buckley, Erin M.
    Hance, Dalton
    Pawlowski, Thomas
    Lynch, Jennifer
    Wilson, Felice B.
    Mesquita, Rickson C.
    Durduran, Turgut
    Diaz, Laura K.
    Putt, Mary E.
    Licht, Daniel J.
    Fogel, Mark A.
    Yodh, Arjun G.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (03)
  • [33] Differentiation of normal and neoplastic bone tissue in dynamic gadolinium-enhanced magnetic resonance imaging: validation of a semiautomated technique
    D'Agostino, F.
    Dell'Aia, P.
    Quattrocchi, C. C.
    Del Vescovo, R.
    Setola, R.
    Grasso, R. F.
    Zobel, B. Beomonte
    RADIOLOGIA MEDICA, 2010, 115 (05): : 804 - 814
  • [34] Noninvasive Quantification of Hepatic Fat Content Using Three-Echo Dixon Magnetic Resonance Imaging With Correction for T2*Relaxation Effects
    Kuehn, Jens-Peter
    Evert, Matthias
    Friedrich, Nele
    Kannengiesser, Stephan
    Mayerle, Julia
    Thiel, Robert
    Lerch, Markus M.
    Dombrowski, Frank
    Mensel, Birger
    Hosten, Norbert
    Puls, Ralf
    INVESTIGATIVE RADIOLOGY, 2011, 46 (12) : 783 - 789
  • [35] Hepatic Fat Quantification Using Chemical Shift MR Imaging and MR Spectroscopy in the Presence of Hepatic Iron Deposition: Validation in Phantoms and in Patients With Chronic Liver Disease
    Lee, Seung Soo
    Lee, Youngjoo
    Kim, Namkug
    Kim, Seong Who
    Byun, Jae Ho
    Park, Seong Ho
    Lee, Moon-Gyu
    Ha, Hyun Kwon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) : 1390 - 1398
  • [36] Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification
    Grimm, Alexandra
    Meyer, Heiko
    Nickel, Marcel D.
    Nittka, Mathias
    Raithel, Esther
    Chaudry, Oliver
    Friedberger, Andreas
    Uder, Michael
    Kemmler, Wolfgang
    Quick, Harald H.
    Engelke, Klaus
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 103 : 57 - 64
  • [37] Measurement of vertebral bone marrow lipid profile at 1.5-T proton magnetic resonance spectroscopy and bone mineral density at dual-energy X-ray absorptiometry: correlation in a swine model
    Di Leo, Giovanni
    Bandirali, Michele
    Fina, Laura
    Messina, Carmelo
    Sardanelli, Francesco
    SKELETAL RADIOLOGY, 2014, 43 (08) : 1123 - 1128
  • [38] Magnetic Resonance Imaging-Based Vertebral Bone Quality Score for Prediction of Cage Subsidence and Screw Loosening in Patients Undergoing Degenerative Lumbar Surgery: A Meta-analysis
    Hu, Fangke
    Xue, Lu
    Zhao, Dong
    Chen, Chao
    Jing, Feng
    Yang, Qiang
    NEUROSPINE, 2024, 21 (03) : 913 - 924
  • [39] Improved T1, Contrast Concentration, and Pharmacokinetic Parameter Quantification in the Presence of Fat with Two-Point Dixon for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Le, Yuan
    Dale, Brian
    Akisik, Fatih
    Koons, Karen
    Lin, Chen
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1677 - 1684
  • [40] Quantification of intramuscular fat in patients with late-onset Pompe disease by conventional magnetic resonance imaging for the long-term follow-up of enzyme replacement therapy
    Lollert, Andre
    Stihl, Clemens
    Hoetker, Andreas M.
    Mengel, Eugen
    Koenig, Jochem
    Laudemann, Katharina
    Goekce, Seyfullah
    Dueber, Christoph
    Staatz, Gundula
    PLOS ONE, 2018, 13 (01):