Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor

被引:84
|
作者
Abreu, FC
Goulart, MOF
Brett, AMO [1 ]
机构
[1] Univ Coimbra, Fac Ciencias & Tecnol, Dept Quim, P-3004535 Coimbra, Portugal
[2] Univ Fed Alagoas, Dept Quim, CCEN, BR-57072970 Maceio, Alagoas, Brazil
[3] Univ Fed Pernambuco, Dept Quim Fundamental, BR-50739 Recife, PE, Brazil
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 11-12期
关键词
DNA biosensor; niclosamide; quantification; reductive activation; electrochemical methods; DNA damage;
D O I
10.1016/S0956-5663(02)00082-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Niclosamide is the only commercially available molluscicide recommended by the WHO for large-scale use in schistosomiasis control programs. The electrochemical reduction and oxidation mechanism of niclosamide was studied using cyclic, differential and square wave voltammetry, at a glassy carbon electrode. An indirect procedure for in situ quantification of niclosamide using batch injection analysis with electrochemical detection, possible to be used for in situ determinations in river streams and effluents, was developed. It enabled a detection limit of 8 x 10(-7) M. The investigation of the niclosamide-DNA interaction using an electrochemical DNA-biosensor showed for the first time clear evidence of interaction with DNA and suggested that niclosamide toxicity can be caused by this interaction, after reductive activation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [11] Electroacoustic miniaturized DNA-biosensor
    Gamby, Jean
    Lazerges, Mathieu
    Pernelle, Christine
    Perrot, Hubert
    Girault, Hubert H.
    Tribollet, Bernard
    LAB ON A CHIP, 2007, 7 (11) : 1607 - 1609
  • [12] Electrochemical DNA biosensor for detection of DNA damage induced by hydroxyl radicals
    Hajkova, Andrea
    Barek, Jiri
    Vyskocil, Vlastimil
    BIOELECTROCHEMISTRY, 2017, 116 : 1 - 9
  • [13] Electro-microchip DNA-biosensor for bacteria detection
    Yeh, Chia Hsien
    Chang, Yu Huai
    Chang, Tsung Chain
    Lin, Hong Ping
    Lin, Yu Cheng
    ANALYST, 2010, 135 (10) : 2717 - 2722
  • [14] Assessment of genotoxicity of catecholics using impedimetric DNA-biosensor
    Ensafi, Ali A.
    Amini, Maryam
    Rezaei, B.
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 43 - 50
  • [15] Simple electrochemical DNA biosensor for detection of DNA damage induced by hydroxyl radicals
    Hajkova, Andrea
    Vyskocil, Vlastimil
    Barek, Jiri
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 19 - 22
  • [16] Voltammetric behavior of nitroimidazoles at a DNA-biosensor
    Brett, AMO
    Serrano, SHP
    Gutz, I
    La-Scalea, MA
    Cruz, ML
    ELECTROANALYSIS, 1997, 9 (14) : 1132 - 1137
  • [17] Voltammetric behaviour of mitoxantrone at a DNA-biosensor
    Brett, AMO
    Macedo, TRA
    Raimundo, D
    Marques, MH
    Serrano, SHP
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8): : 861 - 867
  • [18] Voltammetric Behavior of Nitroimidazoles at a DNA-Biosensor
    Departamento de Química, Universidade de Coimbra, P-3049 Coimbra, Portugal
    不详
    不详
    Electroanalysis, 14 (1132-1137):
  • [19] In situ evaluation of chromium–DNA damage using a DNA-electrochemical biosensor
    S. Carlos B. Oliveira
    A. M. Oliveira-Brett
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1633 - 1641
  • [20] A wireless magnetoelastic DNA-biosensor amplified by AuNPs for the detection of a common mutated DNA causing β-thalassaemia
    Guo, Xing
    Wang, Jingzhe
    Zhao, Yajing
    Liu, Rong
    Zhang, Qiang
    Yuan, Zhongyun
    Sang, Shengbo
    BIOCHEMICAL ENGINEERING JOURNAL, 2020, 156