Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor

被引:84
|
作者
Abreu, FC
Goulart, MOF
Brett, AMO [1 ]
机构
[1] Univ Coimbra, Fac Ciencias & Tecnol, Dept Quim, P-3004535 Coimbra, Portugal
[2] Univ Fed Alagoas, Dept Quim, CCEN, BR-57072970 Maceio, Alagoas, Brazil
[3] Univ Fed Pernambuco, Dept Quim Fundamental, BR-50739 Recife, PE, Brazil
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 11-12期
关键词
DNA biosensor; niclosamide; quantification; reductive activation; electrochemical methods; DNA damage;
D O I
10.1016/S0956-5663(02)00082-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Niclosamide is the only commercially available molluscicide recommended by the WHO for large-scale use in schistosomiasis control programs. The electrochemical reduction and oxidation mechanism of niclosamide was studied using cyclic, differential and square wave voltammetry, at a glassy carbon electrode. An indirect procedure for in situ quantification of niclosamide using batch injection analysis with electrochemical detection, possible to be used for in situ determinations in river streams and effluents, was developed. It enabled a detection limit of 8 x 10(-7) M. The investigation of the niclosamide-DNA interaction using an electrochemical DNA-biosensor showed for the first time clear evidence of interaction with DNA and suggested that niclosamide toxicity can be caused by this interaction, after reductive activation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 50 条
  • [1] Detection of the damage caused to DNA by a thiophene-S-oxide using an electrochemical DNA-biosensor
    Brett, AMO
    da Silva, LA
    Fujii, H
    Mataka, S
    Thiemann, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 549 (SUPPL.) : 91 - 99
  • [2] Voltammetric detection of damage to DNA caused by nitro derivatives of fluorene using an electrochemical DNA biosensor
    Vlastimil Vyskočil
    Ján Labuda
    Jiří Barek
    Analytical and Bioanalytical Chemistry, 2010, 397 : 233 - 241
  • [3] Voltammetric detection of damage to DNA caused by nitro derivatives of fluorene using an electrochemical DNA biosensor
    Vyskocil, Vlastimil
    Labuda, Jan
    Barek, Jiri
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) : 233 - 241
  • [4] A ratiometric electrochemical DNA-biosensor for detection of miR-141
    Khodadoust, Ali
    Nasirizadeh, Navid
    Taheri, Ramezan Ali
    Dehghani, Mohammad
    Ghanei, Mostafa
    Bagheri, Hasan
    MICROCHIMICA ACTA, 2022, 189 (06)
  • [5] An electrochemical DNA biosensor for the detection of DNA damage caused by radioactive iodine and technetium
    Kara, Pinar
    Dagdeviren, Kagan
    Oezsoez, Mehmet
    TURKISH JOURNAL OF CHEMISTRY, 2007, 31 (03) : 243 - 249
  • [6] Electrochemical detection of the toxic dinoflagellate Alexandrium ostenfeldii with a DNA-biosensor
    Metfies, K
    Huljic, S
    Lange, M
    Medlin, LK
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (07): : 1349 - 1357
  • [7] A ratiometric electrochemical DNA-biosensor for detection of miR-141
    Ali Khodadoust
    Navid Nasirizadeh
    Ramezan Ali Taheri
    Mohammad Dehghani
    Mostafa Ghanei
    Hasan Bagheri
    Microchimica Acta, 2022, 189
  • [8] Applications of an electrochemical DNA-biosensor to environmental problems
    Brett, AMO
    Serrano, SHP
    La-Scalea, MA
    BIOSENSORS FOR DIRECT MONITORING OF ENVIRONMENTAL POLLUTANTS IN FIELD, 1997, 38 : 78 - 86
  • [9] Detection of DNA Damage Induced by Hydroquinone and Catechol Using an Electrochemical DNA Biosensor
    Wang, Chuanhu
    Zhao, Jun
    Zhang, Dapeng
    Yang, Zhousheng
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2009, 62 (09) : 1181 - 1184
  • [10] Atomic force microscopy characterization of an electrochemical DNA-biosensor
    Chiorcea, AM
    Brett, AMO
    BIOELECTROCHEMISTRY, 2004, 63 (1-2) : 229 - 232