Monitoring of glucose and glutamate using enzyme microstructures and scanning electrochemical microscopy

被引:6
|
作者
Muresan, Laura [1 ,2 ]
Nistor, Mihaela [2 ]
Gaspar, Szilveszter [3 ]
Popescu, Ionel Catalin [1 ]
Csoregi, Elisabeth [2 ]
机构
[1] Univ Babes Bolyai, Dept Phys Chem, RO-400028 Cluj Napoca, Romania
[2] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[3] Int Ctr Biodynam, RO-060101 Bucharest, Romania
关键词
Enzyme microstructures; Scanning electrochemical microscopy; Glucose oxidase; Glutamate oxidase; H2O2; FEEDBACK MODE; TRANSFER KINETICS; REACTION-RATES; SINGLE CELLS; OXIDASE; SUBSTRATE; ELECTRODE; SURFACES; SECM; VISUALIZATION;
D O I
10.1016/j.bioelechem.2009.05.004
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glucose oxidase and glutamate oxidase lines, with typical width of 100 pm, were patterned on gold surfaces using a micro-dispensing system, by shooting 100 pl droplets of the corresponding enzyme solutions. The probe of a scanning electrochemical microscope (SECM) was then carefully positioned in the close proximity of the enzyme microstructure and poised to + 600 mV vs. Ag/AgCl. KCl 0.1 M. The H2O2, generated by the enzyme lines at different concentrations of glucose and glutamate in the surrounding solution, was sequentially monitored. Reproducible calibration curves for glucose and glutamate were obtained in one single experiment, proving that the combination of enzyme microstructures with SECM can provide a new way of achieving multianalyte detection. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [21] Characterization of Biosensor Surface by Scanning Electrochemical Microscopy
    Morkvenaite-Vilkonciene, I.
    Astrauskaite, I.
    Ramanavicius, A.
    INTELLIGENT TECHNOLOGIES IN LOGISTICS AND MECHATRONICS SYSTEMS, ITELMS 2013, 2013, : 165 - 168
  • [22] Monitoring β-galactosidase activity by means of scanning electrochemical microscopy
    Zhao, C
    Sinha, JK
    Wijayawardhana, CA
    Wittstock, G
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 561 (1-2) : 83 - 91
  • [23] Formation of glucose oxidase microscopic spots by means of electrodeposition with scanning electrochemical microscopy
    Han Shuai-Bing
    Duan Yan-Lin
    Li Fei-Fei
    ACTA CHIMICA SINICA, 2007, 65 (23) : 2750 - 2754
  • [24] Scanning Electrochemical Microscopy for the Study of Energy Accumulators: Principles, Equipment, and Application
    Kolesov, D. V.
    Gorelkin, P. V.
    Prelovskaya, A. O.
    Erofeev, A. S.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2022, 77 (06) : 801 - 810
  • [25] Scanning Electrochemical Microscopy in Neuroscience
    Schulte, Albert
    Nebel, Michaela
    Schuhmann, Wolfgang
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 : 299 - 318
  • [26] Enzyme immunosensing of pepsinogens 1 and 2 by scanning electrochemical microscopy
    Yasukawa, Tomoyuki
    Hirano, Yu
    Motochi, Naomi
    Shiku, Hitoshi
    Matsue, Tomokazu
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) : 3099 - 3104
  • [27] Visualisation of the local electrochemical activity of thermal sprayed anti-corrosion coatings using scanning electrochemical microscopy
    Walsh, Darren A.
    Li, Lisa E.
    Bakare, M. S.
    Voisey, K. T.
    ELECTROCHIMICA ACTA, 2009, 54 (20) : 4647 - 4654
  • [28] Heterogeneous electron transfer kinetics of defective graphene investigated by scanning electrochemical microscopy
    Zhang, Jie
    Guo, Jiayao
    Chen, Duan
    Zhong, Jin-Hui
    Liu, Jun-Yang
    Zhan, Dongping
    APPLIED SURFACE SCIENCE, 2019, 491 : 553 - 559
  • [29] Combined detection of electrochemical reactions and topographical effects - imaging with scanning ohmic microscopy
    Plettenberg, Inka
    Wittstock, Gunther
    ELECTROCHIMICA ACTA, 2016, 197 : 318 - 329
  • [30] Scanning Electrochemical Microscopy of Electrically Heated Wire Substrates
    Wert, Stefan
    Fussstetter, Alexander
    Iffelsberger, Christian
    Matysik, Frank-Michael
    MOLECULES, 2020, 25 (05):