Review on Complete Mueller Matrix Optical Scanning Microscopy Imaging

被引:23
作者
Le Gratiet, Aymeric [1 ,2 ]
Mohebi, Ali [1 ,2 ,3 ]
Callegari, Fabio [1 ,2 ,3 ]
Bianchini, Paolo [1 ,2 ]
Diaspro, Alberto [1 ,2 ,3 ]
机构
[1] Ist Italiano Tecnol, Nanoscopy, Via Morego 30, I-16163 Genoa, Italy
[2] Ist Italiano Tecnol, NIC IIT, Via Morego 30, I-16163 Genoa, Italy
[3] Univ Genoa, Dept Phys, Via Dodecaneso 33, I-16146 Genoa, Italy
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 04期
关键词
polarimetry; mueller matrix; optical scanning microscopy; imaging; POLARIZED-LIGHT; CIRCULAR-DICHROISM; CALIBRATION METHODS; SCATTERING; POLARIMETER; MODULATORS; CAMERA; IMAGER;
D O I
10.3390/app11041632
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Optical scanning microscopy techniques based on the polarization control of the light have the capability of providing non invasive label-free contrast. By comparing the polarization states of the excitation light with its transformation after interaction with the sample, the full optical properties can be summarized in a single 4 x 4 Mueller matrix. The main challenge of such a technique is to encode and decode the polarized light in an optimal way pixel-by-pixel and take into account the polarimetric artifacts from the optical devices composing the instrument in a rigorous calibration step. In this review, we describe the different approaches for implementing such a technique into an optical scanning microscope, that requires a high speed rate polarization control. Thus, we explore the recent advances in term of technology from the industrial to the medical applications.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 79 条
  • [11] DIFFERENTIAL POLARIZATION MICROSCOPE USING AN IMAGE DISSECTOR CAMERA AND PHASE-LOCK DETECTION
    BEACH, DA
    WELLS, KS
    HUSHER, F
    BUSTAMANTE, C
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (11) : 1987 - 1995
  • [12] Angle-resolved Mueller polarimeter using a microscope objective
    Ben Hatit, S.
    Foldyna, M.
    De Martino, A.
    Drevillon, B.
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (04): : 743 - 747
  • [13] MEASURING DIAMETERS OF ROD-SHAPED BACTERIA IN-VIVO WITH POLARIZED-LIGHT SCATTERING
    BRONK, BV
    DRUGER, SD
    CZEGE, J
    VANDEMERWE, WP
    [J]. BIOPHYSICAL JOURNAL, 1995, 69 (03) : 1170 - 1177
  • [14] Confocal scanning laser ophthalmoscopy improvement by use of Mueller-matrix polarimetry
    Bueno, JM
    Campbell, MCW
    [J]. OPTICS LETTERS, 2002, 27 (10) : 830 - 832
  • [15] Double-pass imaging polarimetry in the human eye
    Bueno, JM
    Artal, P
    [J]. OPTICS LETTERS, 1999, 24 (01) : 64 - 66
  • [16] Metrology of Nanostructures by Tomographic Mueller-Matrix Scatterometry
    Chen, Chao
    Chen, Xiuguo
    Shi, Yating
    Gu, Honggang
    Jiang, Hao
    Liu, Shiyuan
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (12):
  • [17] Use of Mueller matrix polarimetry and optical coherence tomography in the characterization of cervical collagen anisotropy
    Chue-Sang, Joseph
    Bai, Yuqiang
    Stoff, Susan
    Gonzalez, Mariacarla
    Holness, Nola
    Gomes, Jefferson
    Jung, Ranu
    Gandjbakhche, Amir
    Chernomordik, Viktor V.
    Ramella-Roman, Jessica C.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (08)
  • [18] General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers
    Compain, E
    Poirier, S
    Drevillon, B
    [J]. APPLIED OPTICS, 1999, 38 (16) : 3490 - 3502
  • [19] POLARIZED-LIGHT SCATTERING OF NUCLEOSOMES AND POLYNUCLEOSOMES - INSITU AND INVITRO STUDIES
    DIASPRO, A
    BERTOLOTTO, M
    VERGANI, L
    NICOLINI, C
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (07) : 670 - 678
  • [20] EXPERIMENTAL DIFFERENTIAL LIGHT-SCATTERING CORRECTION TO CIRCULAR-DICHROISM OF BACTERIOPHAGE T2
    DORMAN, BP
    MAESTRE, MF
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1973, 70 (01) : 255 - 259