Estimated height, weight, and body mass index: Implications for research and patient safety

被引:37
作者
Hendershot, Kimberly M.
Robinson, Linda
Roland, Jason
Vaziri, Khashayar
Rizzo, Anne G.
Fakhry, Samir M.
机构
[1] Inova Fairfax Hosp, Trauma Serv, Falls Church, VA 22042 USA
[2] George Washington Univ Hosp, Trauma Serv, Washington, DC USA
关键词
D O I
10.1016/j.jamcollsurg.2006.08.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: Research suggests that weight influences patient care and outcomes. Health-care providers (HCPs) sometimes rely on patient self-reports or HCP estimates of height and weight. The purpose of this study was to determine the accuracy of self-reported height and weight and HCP estimations of height, weight, and body mass index (BMI) classification when compared with measured height, weight, and calculated BMI. STUDY DESIGN: Attending physicians, residents, and nurses provided height and weight estimates along with BMI categorizations for 110 trauma patients at a large, teaching hospital with a Level I trauma center. Patients provided reports of their heights and weights. Measured heights and weights were obtained with appropriate calibrated devices, and BMIs were calculated. Estimates and categorizations were then compared with measured and calculated values. RESULTS: HCPs were 41% and 53% accurate in estimating height and weight, respectively. Self-reports had higher accuracy (69% and 92%, respectively) but still resulted in a BMI misclassification of 32%. Twenty-two percent of patient self-reports were unobtainable. When HCPs attempted to categorize a patient into a BMI group, the accuracy was 56%. Functioning, calibrated instruments for measuring height and weight were frequently unavailable in relevant hospital locations. CONCLUSIONS: This study demonstrated that HCPs' estimates of height, weight, and BMI category are highly inaccurate. Patient self-reports are better, but are unavailable at times. Objective measurements with calibrated instruments are necessary for accuracy in research studies and for patient safety in clinical practice. Efforts to ensure the availability of calibrated instruments may be necessary in the hospital setting.
引用
收藏
页码:887 / 893
页数:7
相关论文
共 6 条
  • [1] *AM OB ASS, AOA FACT SHEETS
  • [2] [Anonymous], 1998, CLIN GUID ID EV TREA
  • [3] *CDC, 1999, PREV OV OB AD US
  • [4] AVAILABILITY AND ADEQUACY OF DIAGNOSTIC AND THERAPEUTIC EQUIPMENT FOR THE MORBIDLY OBESE PATIENT IN AN ACUTE CARE SETTING
    FOIL, MB
    COLLIER, MS
    MACDONALD, KG
    PORIES, WJ
    [J]. OBESITY SURGERY, 1993, 3 (02) : 153 - 156
  • [5] Larkin H, 2004, HOSP HEALTH NETWORK, V78, P58
  • [6] Estimated risks for developing obesity in the Framingham Heart Study
    Vasan, RS
    Pencina, MJ
    Cobain, M
    Freiberg, MS
    D'Agostino, RB
    [J]. ANNALS OF INTERNAL MEDICINE, 2005, 143 (07) : 473 - 480