Thermoluminescence in CVD diamond films:: Application to actinometric dosimetry

被引:5
作者
Barboza-Flores, M
Meléndrez, R
Chernov, V
Castañeda, B
Pedroza-Montero, M
Gan, B
Ahn, J
Zhang, Q
Yoon, SF
机构
[1] Univ Sonora, Ctr Invest & Fis, Hermosillo 83190, Sonora, Mexico
[2] CICESE, Program Posgrado & Fis Mat, Ensenada 22800, Baja California, Mexico
[3] Nanyang Technol Univ, Microelect Ctr, Singapore 639798, Singapore
关键词
D O I
10.1093/oxfordjournals.rpd.a005909
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Diamond is considered a tissue-equivalent material since its atomic number (Z = 6) is close to the effective atomic number of biological tissue (Z = 7.42). Such a situation makes it suitable for radiation detection purposes in medical applications. In the present work the analysis is reported of the thermoluminescence (TL) and dosimetric features of chemically vapour deposited (CVD) diamond film samples subjected to ultraviolet (UV) irradiation in the actinometric region. The TL glow curve shows peaks at 120, 220, 320 and 370degreesC. The 120 and 370degreesC peaks are too weak and the first one fades away in a few seconds after exposure. The overall room temperature fading shows a 50% TL decay 30 min after exposure. The 320degreesC glow peak is considered to be the most adequate for dosimetric applications due to its low fading and linear TL behaviour as a function of UV dose in the 180-260 nm range. The TL excitation spectrum presents a broad band with at least two overlapped components around 205 and 220 nm. The results indicate that the TL behaviour of CVD diamond film can be a good alternative to the currently available dosemeter and detector in the actinometric region as well as in clinical and medical applications.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 9 条
[1]   Thermoluminescent behaviour of diamond films subjected to UV irradiation [J].
Apátiga, LM ;
Castaño, VM ;
Golzarri, JI ;
García, J ;
Alba, F .
MATERIALS RESEARCH INNOVATIONS, 1999, 3 (03) :156-159
[2]   Selected thermoluminescent properties of CVD diamond film [J].
Benabdesselam, M ;
Iacconi, P ;
Briand, D ;
Lapraz, D ;
Butler, JE .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :257-260
[3]   Luminescence and conductivity studies on CVD diamond exposed to UV light [J].
Bizzarri, A ;
Bogani, F ;
Bruzzi, M ;
Sciortino, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01) :169-172
[4]   Assessment of CVD diamond as a thermoluminescence dosemeter material [J].
Borchi, E ;
Furetta, C ;
Kitis, G ;
Leroy, C ;
Sussmann, RS ;
Whitehead, AJ .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :291-295
[5]   TSC response of irradiated CVD diamond films [J].
Borchi, E ;
Bruzzi, M ;
Bucciolini, M ;
Guasti, A ;
Mazzocchi, S ;
Pirollo, S ;
Sciortino, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01) :181-184
[6]   Thermoluminescence characteristics of a new production of chemical vapour deposition diamond [J].
Furetta, C ;
Kitis, G ;
Brambilla, A ;
Jany, C ;
Bergonzo, P ;
Foulon, F .
RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) :201-205
[7]   Stability of polycrystalline diamond films as UV thermoluminescent dosimeters [J].
Mumford, JW ;
Apátiga, LM ;
Golzarri, JI ;
Castaño, VM .
MATERIALS LETTERS, 1998, 37 (06) :330-333
[8]   Thermally stimulated current investigations on diamond x-ray detectors [J].
Tromson, D ;
Bergonzo, P ;
Brambilla, A ;
Mer, C ;
Foulon, F ;
Amosov, VN .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (07) :3360-3364
[9]   Thermoluminescence in CVD diamond films: application to radiation dosimetry [J].
Vittone, E ;
Manfredotti, C ;
Fizzotti, F ;
Lo Giudice, A ;
Polesello, P ;
Ralchenko, V .
DIAMOND AND RELATED MATERIALS, 1999, 8 (07) :1234-1239