On the reproducibility of transducer coupling for acoustic emission testing

被引:2
|
作者
Hensman, J. J. [1 ]
Cristodaro, C., V [2 ]
Pierce, S. G. [1 ]
Worden, K. [1 ]
机构
[1] Univ Sheffield, Dynam Res Grp, Dept Mech Engn, Mappin St, Sheffield S1 3JD, S Yorkshire, England
[2] Politecn Torino, Dept Ingn Meccan, I-10129 Turin, Italy
来源
ACOUSTIC EMISSION TESTING | 2006年 / 13-14卷
关键词
acoustic emission; transducer coupling; fatigue; cross-correlation;
D O I
10.4028/www.scientific.net/AMR.13-14.117
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An acoustic emission test was simulated using a three point bend specimen and an artificial. AE source. Waveform data was recorded as the sample was cyclically loaded in three point bending, and the cross correlation coefficient of the waveforms was used to measure the repeatability of the test. Results were twofold: the stress state of a specimen affects the ultrasonic propagation therein; and the coupling condition of a transducer may not remain constant during a test.
引用
收藏
页码:117 / +
页数:2
相关论文