Differential receptors create patterns diagnostic for ATP and GTP

被引:194
作者
McCleskey, SC [1 ]
Griffin, MJ [1 ]
Schneider, SE [1 ]
McDevitt, JT [1 ]
Anslyn, EV [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ja021230b
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein we report the combination of a library of resin-bound sensors along with a multicomponent sensor array. This novel combinatorial array sensor system shows selectivity for nucleotide phosphates in solution. The design of the anchored receptor includes a 1,3,5-trisubstituted-2,4,6-triethylbenzene scaffold coupled with peptide libraries. Each chemosensor is placed into a micromachined cavity within a silicon wafer, and the optical changes observed by a charged-coupled device result in near-real-time digital analysis of solutions. A colorimetric displacement assay was performed, and time-dependent imaging studies of the selected sensing ensembles result in a differential responses upon addition of adenosine 5′-triphosphate (ATP), adenosine 5′-monophosphate (AMP), or guanosine 5′-triphosphate (GTP). An advantage to this approach is that it creates an array of sensors that gives a fingerprint response for each analyte. Principal component analysis indicates that the library of chemosensors can differentiate between ATP, GTP, and AMP. On the basis of factor loading values, individual sensors from the library were sequenced to elucidate their chemical composition. Copyright © 2003 American Chemical Society.
引用
收藏
页码:1114 / 1115
页数:2
相关论文
共 15 条
  • [1] Cross-reactive chemical sensor arrays
    Albert, KJ
    Lewis, NS
    Schauer, CL
    Sotzing, GA
    Stitzel, SE
    Vaid, TP
    Walt, DR
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2595 - 2626
  • [2] SELECTION OF ADSORBATES FOR CHEMICAL SENSOR ARRAYS BY PATTERN-RECOGNITION
    CAREY, WP
    BEEBE, KR
    KOWALSKI, BR
    ILLMAN, DL
    HIRSCHFELD, T
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (01) : 149 - 153
  • [3] Characterization of a cross-reactive electronic nose with vapoluminescent array elements
    Drew, SM
    Janzen, DE
    Mann, KR
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (11) : 2547 - 2555
  • [4] Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities
    Goodey, A
    Lavigne, JJ
    Savoy, SM
    Rodriguez, MD
    Curey, T
    Tsao, A
    Simmons, G
    Wright, J
    Yoo, SJ
    Sohn, Y
    Anslyn, EV
    Shear, JB
    Neikirk, DP
    McDevitt, JT
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (11) : 2559 - 2570
  • [5] MULTICHANNEL TASTE SENSOR USING LIPID-MEMBRANES
    HAYASHI, K
    YAMANAKA, M
    TOKO, K
    YAMAFUJI, K
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 2 (03) : 205 - 213
  • [6] Computational methods for the analysis of chemical sensor array data from volatile analytes
    Jurs, PC
    Bakken, GA
    McClelland, HE
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2649 - 2678
  • [7] Lavigne J. J., 1999, ANGEW CHEM, V111, P3903
  • [8] Lavigne JJ, 2001, ANGEW CHEM INT EDIT, V40, P3118, DOI 10.1002/1521-3773(20010903)40:17<3118::AID-ANIE3118>3.0.CO
  • [9] 2-Y
  • [10] Array-based vapor sensing using chemically sensitive, carbon black-polymer resistors
    Lonergan, MC
    Severin, EJ
    Doleman, BJ
    Beaber, SA
    Grubb, RH
    Lewis, NS
    [J]. CHEMISTRY OF MATERIALS, 1996, 8 (09) : 2298 - 2312