Reproducibility of myelin water fraction analysis: a comparison of region of interest and voxel-based analysis methods

被引:56
作者
Meyers, Sandra M. [2 ]
Laule, Cornelia [1 ]
Vavasour, Irene M. [1 ]
Kolind, Shannon H. [3 ]
Madler, Burkhard [3 ,4 ]
Tam, Roger [1 ]
Traboulsee, Anthony L. [5 ]
Lee, Jimmy [5 ]
Li, David K. B. [1 ]
MacKay, Alex L. [1 ,3 ]
机构
[1] Univ British Columbia, Dept Radiol, Vancouver, BC V6T 2B5, Canada
[2] Univ Alberta, Dept Phys, Edmonton, AB T6G 2G7, Canada
[3] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada
[4] Philips Healthcare, Vancouver, BC V6T 2B5, Canada
[5] Univ British Columbia, Dept Med, Vancouver, BC V6T 2B5, Canada
关键词
Myelin water; T-2; relaxation; NNLS; White matter; Voxel-based analysis; MULTIPLE-SCLEROSIS; T2; RELAXATION; IN-VIVO; MAGNETIZATION-TRANSFER; TRANSVERSE RELAXATION; T-2; BRAIN; MRI; DISTRIBUTIONS; COMPONENTS;
D O I
10.1016/j.mri.2009.02.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study compared region of interest (ROI) and voxel-based analysis (VBA) methods to determine the optimal method of myelin water fraction (MWF) analysis. Twenty healthy controls were scanned twice using a multi-echo T-2 relaxation sequence and ROIs were drawn in white and grey matter. MWF was defined as the fractional signal from 15 to 40 ms in the T-2 distribution. For ROI analysis, the mean intensity of voxels within an ROI was fit using non-negative least squares. For VBA, MWF was obtained for each voxel and the mean and median values within an ROI were calculated. There was a slightly higher correlation between Scan I and 2 for the VBA method (R-2=0.98) relative to the ROI method (R-2=0.95), and the VBA mean square difference between scans was 300% lower, indicating VBA was the most consistent between scans. For the VBA method, mean MWF was found to be more reproducible than median MWF. As the VBA method is more reproducible and gives more options for visualization and analysis of MWF, it is recommended over the ROI method of MWF analysis. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 39 条
[1]   INVIVO DETERMINATION OF MULTIEXPONENTIAL T2 RELAXATION IN THE BRAIN OF PATIENTS WITH MULTIPLE-SCLEROSIS [J].
ARMSPACH, JP ;
GOUNOT, D ;
RUMBACH, L ;
CHAMBRON, J .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :107-113
[2]   Multicomponent water proton transverse relaxation and T2-discriminated water diffusion in myelinated and nonmyelinated nerve [J].
Beaulieu, C ;
Fenrich, FR ;
Allen, PS .
MAGNETIC RESONANCE IMAGING, 1998, 16 (10) :1201-1210
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   T-2 RELAXATION OF PERIPHERAL-NERVE MEASURED IN-VIVO [J].
DOES, MD ;
SNYDER, RE .
MAGNETIC RESONANCE IMAGING, 1995, 13 (04) :575-580
[5]   Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2* decay at 3T:: A preliminary postmortem study [J].
Du, Yiping P. ;
Chu, Renxin ;
Hwang, Dosik ;
Brown, Mark S. ;
Kleinschmidt-DeMasters, Bette K. ;
Singel, Debra ;
Simon, Jack H. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :865-870
[6]   Relaxation times and microstructures [J].
Fenrich, FRE ;
Beaulieu, C ;
Allen, PS .
NMR IN BIOMEDICINE, 2001, 14 (02) :133-+
[7]   Quantitative perfusion measurements using pulsed arterial spin labeling: Effects of large region-of-interest analysis [J].
Figueiredo, PM ;
Clare, S ;
Jezzard, P .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) :676-682
[8]   Abnormalities of myelination in schizophrenia detected in vivo with MRI, and post-mortem with analysis of oligodendrocyte proteins [J].
Flynn, SW ;
Lang, DJ ;
Mackay, AL ;
Goghari, V ;
Vavasour, IM ;
Whittall, KP ;
Smith, GN ;
Arango, V ;
Mann, JJ ;
Dwork, AJ ;
Falkai, P ;
Honer, WG .
MOLECULAR PSYCHIATRY, 2003, 8 (09) :811-820
[9]   Optimized spiral imaging for measurement of myocardial T2 relaxation [J].
Foltz, WD ;
Al-Kwifi, O ;
Sussman, MS ;
Stainsby, JA ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1089-1097
[10]   Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis [J].
Galbraith, SM ;
Lodge, MA ;
Taylor, NJ ;
Rustin, GJS ;
Bentzen, S ;
Stirling, JJ ;
Padhani, AR .
NMR IN BIOMEDICINE, 2002, 15 (02) :132-142