The spectral response of silicon X-ray detectors

被引:24
作者
Eggert, T. [1 ]
Boslau, O. [1 ]
Kemmer, J. [1 ]
Pahke, A. [1 ]
Wiest, F. [1 ]
机构
[1] KETEK GmbH, D-81737 Munich, Germany
关键词
silicon drift detector; SDD; Si(Li); background; partial events; incomplete charge collection; BESSY; 2;
D O I
10.1016/j.nima.2006.07.011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A discrete analytic calculation of the spectral response of silicon drift detectors for X-rays is presented. The results are compared with measurements at BESSY II using monochromatic synchrotron radiation in the energy range from 0.2 to 2 keV. All Gaussian features (main, escape, and Al fluorescence peak) as well as the background are included in the model. The peak intensities are calculated from energy dependent probability distributions. The non-Gaussian background is produced by charge-loss in the entrance window. The charge loss of energetic photo and Auger electrons and the diffusion of low-energy secondary electrons into the aluminum dead layer are considered. The secondary electrons disperse in a Gaussian charge distribution with the width sigma(sec), which is the only free parameter of the model. All collected charge is summed up for every possible process and convoluted with electronic and Fano noise, yielding the energy distribution of the background. Its intensity is given by the probability of the process. This method generates all observed spectral background features using a single fundamental calculation scheme. It can, in principle, be applied to any type of semiconductor detector. The calculations are in very good agreement with the measurements. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 26 条
[1]   SCATTERING BY IONIZATION AND PHONON EMISSION IN SEMICONDUCTORS .2. MONTE-CARLO CALCULATIONS [J].
ALIG, RC .
PHYSICAL REVIEW B, 1983, 27 (02) :968-977
[2]   SCATTERING BY IONIZATION AND PHONON EMISSION IN SEMICONDUCTORS [J].
ALIG, RC ;
BLOOM, S ;
STRUCK, CW .
PHYSICAL REVIEW B, 1980, 22 (12) :5565-5582
[3]   Simulations of Si(Li) x-ray detector response [J].
Campbell, JL ;
McDonald, L ;
Hopman, T ;
Papp, T .
X-RAY SPECTROMETRY, 2001, 30 (04) :230-241
[4]   A quantitative explanation of low-energy tailing features of Si(Li) and Ge X-ray detectors, using synchrotron radiation [J].
Campbell, JL ;
Cauchon, G ;
Lepy, MC ;
McDonald, L ;
Plagnard, J ;
Stemmler, P ;
Teesdale, WJ ;
White, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3) :394-404
[5]  
CROMER DT, 1970, LA4403 LOS AL SCI LA, P163
[6]   Silicon drift detectors with enlarged sensitive areas [J].
Eggert, T ;
Boslau, O ;
Goldstrass, P ;
Kemmer, J .
X-RAY SPECTROMETRY, 2004, 33 (04) :246-252
[7]   Analysis of background events in Silicon Drift Detectors [J].
Eggert, T ;
Goldstrass, P ;
Kemmer, J ;
Pahlke, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (1-2) :257-264
[8]  
Eggert T., 2004, THESIS TU MUNCHEN
[9]  
EGGERT T, 2004, ADV XRAY ANAL, V48
[10]   THE X-RAY-ENERGY RESPONSE OF SILICON .A. THEORY [J].
FRASER, GW ;
ABBEY, AF ;
HOLLAND, A ;
MCCARTHY, K ;
OWENS, A ;
WELLS, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :368-378