Interferometric study of natural convection heat transfer phenomena around array of heated cylinders

被引:42
|
作者
Narayan, Surya [1 ]
Singh, Abhimanyu K. [1 ]
Srivastava, Atul [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
关键词
Laser interferometry; Continuous wavelet transform; Heated cylinders; Natural convection; Plume interaction; CONTINUOUS WAVELET TRANSFORM; HORIZONTAL CYLINDERS; TEMPERATURE IMBALANCE; SEPARATION DISTANCE; EQUATIONS; FLOW; LAMINAR; FIELD; AIR;
D O I
10.1016/j.ijheatmasstransfer.2017.01.106
中图分类号
O414.1 [热力学];
学科分类号
摘要
Interferometric measurements of natural convection-based heat transfer rates around array(s) of heated cylinders have been presented. Experiments have been performed with single, two cylinders placed adjacent to each other with varying centre-to-centre distances and three cylinders arranged in a triangular configuration. Mach-Zehnder interferometer has been employed for recording the projection data of temperature field. The interferograms have first been qualitatively interpreted to understand the influence of buoyant plume of one cylinder on the convective phenomena of the other cylinder(s) of the array. Images have then been quantitatively analyzed to retrieve the whole field temperature distributions. Results have been presented in the form of interferometric images, temperature contours, local distribution of heat transfer rates as a function of Rayleigh numbers. Experiments involving two cylinders showed a strong dependence of the net convective phenomena on the relative spacing of the cylinders. While the buoyant plumes originating from each cylinder were almost independent of each other for larger centre-to-centre distances, the plumes were seen to be strongly coupled as the spacing between the cylinders was reduced. Wall heat transfer rates were found to be comparable with those of single cylinder for large cylinder centre-to-centre distances and showed a decreasing trend as the relative spacing is reduced. Experiments on the triangular array of cylinders revealed that the heat transfer rates from the top cylinder were strongly influenced by the thermal plumes rising from the bottom cylinders. The average Nusselt number around the top cylinder in triangular configuration was found to be significantly smaller than that of the single cylinder. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:278 / 292
页数:15
相关论文
共 50 条
  • [1] Natural convection heat transfer of molten salt nanofluids around vertical array of heated horizontal cylinders
    Yu, Qiang
    Lu, Yuanwei
    Peng, Dawen
    Wu, Yuting
    Ma, Chongfang
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2018, 74 (10) : 1666 - 1684
  • [2] NATURAL-CONVECTION HEAT-TRANSFER AROUND A HORIZONTAL ARRAY OF HEATED CYLINDERS IN AIR
    KURIYAMA, M
    TOKANAI, H
    HARADA, E
    KONNO, H
    KAGAKU KOGAKU RONBUNSHU, 1995, 21 (03) : 514 - 520
  • [3] Fluid Flow and Heat Transfer of Natural Convection Around Array of Vertical Heated Plates
    Kitamura, Kenzo
    Mitsuishi, Akihiko
    Misumi, Toshiyuki
    HEAT TRANSFER-ASIAN RESEARCH, 2009, 38 (02): : 101 - 117
  • [4] Natural convection heat transfer and boundary layer transition for vertical heated cylinders
    Goodrich, Samuel S.
    Marcum, Wade R.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 105 : 367 - 380
  • [5] Fluid flow and heat transfer of natural convection induced around a vertical row of heated horizontal cylinders
    Kitamura, K.
    Mitsuishi, A.
    Suzuki, T.
    Kimura, F.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 : 414 - 429
  • [6] Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders
    Khanafer, K.
    Aithal, S. M.
    Vafai, K.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 135 : 117 - 132
  • [7] Fluid flow and heat transfer of natural convection around heated vertical cylinders - (Effect of cylinder diameter)
    Kimura, F
    Tachibana, T
    Kitamura, K
    Hosokawa, T
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2004, 47 (02) : 156 - 161
  • [8] NUMERICAL MODELING OF NATURAL CONVECTION HEAT TRANSFER AROUND HORIZONTAL TRIANGULAR CYLINDERS
    Alansary, H.
    Zeitoun, O.
    Ali, M.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2012, 61 (03) : 201 - 219
  • [9] Natural convection heat transfer within a square porous enclosure with four heated cylinders
    Nammi, Govindarao
    Deka, Dhrijit Kumar
    Pati, Sukumar
    Baranyi, Laszlo
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 30
  • [10] NATURAL CONVECTION HEAT TRANSFER AROUND TWO HEATED CYLINDERS IN AN ISOTHERMAL ENCLOSURE INCLUDING THE EFFECT OF WALL CONDUCTANCE
    Lacroix, Marcel
    Joyeux, Antoine
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 1994, 4 (01) : 465 - 476