Subcooling effect on air-conditioning system by simulation analysis

被引:3
作者
Karthik, R. [1 ]
Karthik, A. Gokul [1 ]
Kumar, K. Mohan [1 ]
机构
[1] Sri Shakthi Inst Engn & Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
关键词
Air-conditioning system; Coefficient of Performance; Subcooling; Evaporative cooling; Coefficient of performance; CO2 REFRIGERATION CYCLE; PERFORMANCE IMPROVEMENT; CONDENSER;
D O I
10.1016/j.matpr.2020.06.310
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Air-conditioning systems are mainly used in industries and residences to maintain the low temperature and required humidity level. More energy is consumed in air-conditioning systems. Coefficient of Performance (COP) is an important factor for the measure of air-conditioning system performance. Sub cooling is the concept used to reduce the condenser temperature. Sub cooling concept can be obtained by many methods like Humidification, Evaporative cooling etc. In order to optimize the performance of air conditioning systems, the condenser temperature is decreased by evaporative cooling. This approach can be applied to existing air-conditioning system to increase its performance and reduce the energy consumption. Simulation work has been carried out to study the performance of air-conditioning system with sub cooling concept. The condenser heat rejection rate is increased about 5.37%. By reducing condenser temperature about 2 degrees C, COP is increased about 1.86%. When the condenser temperature is reduced by 4 degrees C, COP is increased about 2.65%. Similarly same process is carried out for 6 degrees C, 8 degrees C and 10 degrees C; the COP improved about 3.98%, 5.5%, and 6.86% respectively. This simulation work provides an improvement in COP value and the results are compared with and without subcooling concept. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 50 条
  • [21] Simulation and experiment study of neural network PID controller in central air-conditioning system
    Wang, Jiangjiang
    An, Dawei
    2006 IEEE CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS, VOLS 1 AND 2, 2006, : 598 - +
  • [22] Design of monitored control system for central air-conditioning system
    Wang, Jiangjiang
    Jing, Youyin
    Zhan, Chunfa
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 80 - 86
  • [23] Factor analysis and optimization of operational parameters in a liquid desiccant air-conditioning system
    Tu, Min
    Huang, Hui
    Liu, Ze-Hua
    Chen, Huan-Xin
    Ren, Cheng-Qin
    Chen, Guo-Jie
    Hu, Yan
    ENERGY, 2017, 139 : 767 - 781
  • [24] Exergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System
    Liao, Ke Yang
    Chuah, Yew Khoy
    ENTROPY, 2016, 18 (03)
  • [25] Applicability of sewage heat pump air-conditioning system
    Chen Jin-hua
    Liu Meng
    Liu Yong
    Jin Ming
    Chen Jie
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 183 - 187
  • [26] Applicability of sewage heat pump air-conditioning system
    陈金华
    刘猛
    刘勇
    靳鸣
    陈洁
    Journal of Central South University, 2009, 16 (S1) : 183 - 187
  • [27] Performance analysis and improvement of air filtration and ventilation process in semiconductor clean air-conditioning system
    Ma, Zhiyao
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    ENERGY AND BUILDINGS, 2020, 228
  • [28] A New Air-conditioning System with Chilled Water Storage
    Lin, Hu
    Li, Xinhong
    Cheng, Pengsheng
    Xu, Bugong
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 2964 - +
  • [29] Quantification on the Effects of Liquid-Vapor Separation in Air-Conditioning System by using Advanced Exergy Analysis
    Li, Yunhai
    Chen, Jianyong
    Lin, Xu
    Yang, Zhi
    Chen, Ying
    Luo, Xianglong
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (03) : 597 - 608
  • [30] Variable air volume air-conditioning experiment system with advanced controls
    Meng, Qinglong
    Yan, Xiuying
    Ren, Qingchang
    Adeli, Hojjat
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (01) : 114 - 127