Superparamagnetic iron-oxide-enhanced diffusion-weighted magnetic resonance imaging for the diagnosis of intrapancreatic accessory spleen

被引:6
|
作者
Ishigami, Kousei [1 ]
Nishie, Akihiro [1 ]
Nakayama, Tomohiro [1 ]
Asayama, Yoshiki [1 ]
Kakihara, Daisuke [1 ]
Fujita, Nobuhiro [1 ]
Ushijima, Yasuhiro [1 ]
Okamoto, Daisuke [1 ]
Ohtsuka, Takao [2 ]
Mori, Yasuhisa [2 ]
Ito, Tetsuhide [3 ]
Mochidome, Naoki [4 ]
Honda, Hiroshi [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[2] Kyushu Univ, Grad Sch Med Sci, Surg & Oncol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Med & Bioregulatory Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
[4] Kyushu Univ, Grad Sch Med Sci, Anat Pathol, Higashi Ku, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
关键词
Intrapancreatic accessory spleen; Superparamagnetic iron oxide; Diffusion-weighted image; Pancreatic tumor; Diagnostic performance; FINE-NEEDLE-ASPIRATION; EPIDERMOID CYST; CONTRAST AGENTS; MR FINDINGS; ULTRASONOGRAPHY; PANCREAS; TUMOR; MASS;
D O I
10.1007/s00261-019-02189-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the diagnostic performance of superparamagnetic iron-oxide (SPIO)-enhanced diffusion-weighted image (DWI) for distinguishing an intrapancreatic accessory spleen from pancreatic tumors. Materials and methods Twenty-six cases of intrapancreatic accessory spleen and nine cases of pancreatic tail tumors [neuroendocrine tumor (n = 8) and pancreatic adenocarcinoma (n = 1)] were analyzed. Two blind reviewers retrospectively reviewed the SPIO-enhanced magnetic resonance imaging (MRI) scans. The lesion visibility grades were compared and the diagnostic performance of SPIO-enhanced DWI was compared to those of SPIO-enhanced T2WI and T2*WI with the use of a receiver operating characteristic (ROC) analysis. Results The grade of lesion visibility was the highest on DWI [mean +/- standard deviation (SD): 2.8 +/- 0.3] followed by T2WI (2.3 +/- 0.7, p < 0.001) and T2*WI (2.1 +/- 0.7, p < 0.0001). Reviewers 1 and 2 correctly characterized the presence or absence of SPIO uptake in 34 of 35 cases (97.1%) on DWI, 24 (68.6%) and 25 (71.4%) cases on T2WI, respectively, and 16 (45.7%) and 17 (48.6%) cases on T2*WI. The area under the ROC curve (AUC) of DWI was 0.974 and 0.989 for reviewers 1 and 2, respectively. For Reviewer 1, the AUC of DWI was significantly higher than that of T2*WI (0.756, p < 0.01), although it was not significantly different from that of T2WI (0.868, p = 0.0857). For Reviewer 2, the AUC of DWI was significantly higher than those of T2WI (0.846, p < 0.05) and T2*WI (0.803, p < 0.01). Conclusion The diagnostic performance of SPIO-enhanced DWI was better than those of SPIO-enhanced T2*WI and T2WI for the diagnosis of intrapancreatic accessory spleen.
引用
收藏
页码:3325 / 3335
页数:11
相关论文
共 50 条
  • [31] Differentiation of subtypes of renal cell carcinoma: dynamic contrast-enhanced magnetic resonance imaging versus diffusion-weighted magnetic resonance imaging
    Yamamoto, Akira
    Tamada, Tsutomu
    Ito, Katsuyoshi
    Sone, Teruki
    Kanki, Akihiko
    Tanimoto, Daigo
    Noda, Yasufumi
    CLINICAL IMAGING, 2017, 41 : 53 - 58
  • [32] Iron-oxide-enhanced magnetic resonance imaging of atherosclerotic plaques - Postmortem analysis of accuracy, inter-observer agreement, and pitfalls
    Schmitz, SA
    Taupitz, M
    Wagner, S
    Coupland, SE
    Gust, R
    Nikolova, A
    Wolf, KJ
    INVESTIGATIVE RADIOLOGY, 2002, 37 (07) : 405 - 411
  • [33] Role of Magnetic Resonance Diffusion-Weighted Imaging in Differentiating Lacrimal Masses
    Zhang, Fang
    Sha, Yan
    Qian, Jiang
    Huang, Wen-hu
    Li, Xiao-Feng
    Wang, Shen-jiang
    Ye, Xin-Pei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) : 641 - 648
  • [34] Diffusion-weighted imaging and conventional magnetic resonance imaging for detection of non-palpable undescended testis
    Mohammed, Nagwa Emad Ali
    Badwey, Manal Ezzat
    Nagla, Salah Abdelmonsef
    Dawoud, Rasha Mahmoud
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [35] Quantitative assessment of iron-oxide-enhanced magnetic resonance imaging of the liver: Vessel isointensity is a potential characteristic of liver hemangiomas on late T1-weighted images
    Schmitz, S. A.
    Nikolova, A.
    O'Regan, D.
    Albrecht, T.
    Hohmann, J.
    Wolf, K. -J.
    ACTA RADIOLOGICA, 2006, 47 (07) : 634 - 642
  • [36] Detection of Small Hepatocellular Carcinoma Can Gadoxetic Acid-Enhanced Magnetic Resonance Imaging Replace Combining Gadopentetate Dimeglumine-Enhanced and Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging?
    Kim, Young Kon
    Kim, Chong Soo
    Han, Young Min
    Park, Gun
    INVESTIGATIVE RADIOLOGY, 2010, 45 (11) : 740 - 746
  • [37] Potential of Noncontrast Magnetic Resonance Imaging With Diffusion-Weighted Imaging in Characterization of Breast Lesions Intraindividual Comparison With Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Baltzer, Pascal A. T.
    Bickel, Hubert
    Spick, Claudio
    Wengert, Georg
    Woitek, Ramona
    Kapetas, Panagiotis
    Clauser, Paola
    Helbich, Thomas H.
    Pinker, Katja
    INVESTIGATIVE RADIOLOGY, 2018, 53 (04) : 229 - 235
  • [38] Differential Diagnosis of Benign and Malignant Distal Biliary Strictures: Value of Adding Diffusion-Weighted Imaging to Conventional Magnetic Resonance Cholangiopancreatography
    Yoo, Roh-Eul
    Lee, Jeong Min
    Yoon, Jeong Hee
    Kim, Jung Hoon
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1509 - 1517
  • [39] Magnetic resonance angiography of the portal venous system enhanced by superparamagnetic iron oxide
    Schmitz, SA
    Jensen, K
    Wolf, KJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (01): : 51 - 54
  • [40] Accuracy of combined dynamic contrast-enhanced magnetic resonance imaging and diffusion-weighted imaging for breast cancer detection: a meta-analysis
    Zhang, Li
    Tang, Min
    Min, Zhiqian
    Lu, Jun
    Lei, Xiaoyan
    Zhang, Xiaoling
    ACTA RADIOLOGICA, 2016, 57 (06) : 651 - 660