Pre-concentration of phenolic compounds in water samples by novel liquid-liquid microextraction and determination by gas chromatography-mass spectrometry

被引:59
作者
Faraji, Hakim [1 ]
Tehrani, Mohammad Saber [1 ]
Husain, Syed Waqif [1 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Chem, Sci & Res Branch, Tehran, Iran
关键词
Phenolic compounds; LPME; Water sample; Derivatization; GC-MS; SOLID-PHASE MICROEXTRACTION; ELECTRON-CAPTURE DETECTION; BAR SORPTIVE EXTRACTION; VOLATILE PHENOLS; SOLVENT MICROEXTRACTION; OPTIMIZATION; DERIVATIZATION; CHLOROPHENOLS; PESTICIDES; WINES;
D O I
10.1016/j.chroma.2009.10.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pre-concentration and determination of 8 phenolic compounds in water samples has been achieved by in situ derivatization and using a new liquid-liquid microextraction coupled GC-MS system. Microextraction efficiency factors have been investigated and optimized: 9 mu L 1-undecanol microdrop exposed for 15 min floated on surface of a 10 mL water sample at 55 degrees C, stirred at 1200 rpm, low pH level and saturated salt conditions. Chromatographic problems associated with free phenols have been overcome by simultaneous in situ derivatization utilizing 40 mu L of acetic anhydride and 0.5% (w/v) K2CO3. Under the selected conditions, pre-concentration factor of 235-1174, limit of detection of 0.005-0.68 mu g/L (S/N=3) and linearity range of 0.02-300 mu g/L have been obtained. A reasonable repeatability (RSD <= 10.4%, n=5) with satisfactory linearity (0.9995 >= r(2) >= 0.9975) of results illustrated a good performance of the present method. The relative recovery of different natural water samples was higher than 84%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:8569 / 8574
页数:6
相关论文
共 30 条
[1]  
[Anonymous], TRENDS ANAL CHEM
[2]   Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry [J].
Bagheri, H ;
Saber, A ;
Mousavi, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :27-33
[3]   New polymeric sorbent for the solid-phase extraction of chlorophenols from water samples followed by gas chromatography-electron-capture detection [J].
Bagheri, H ;
Saraji, M .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :87-93
[4]   Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :161-169
[5]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[6]  
CHATONNET P, 1988, SCI ALIMENT, V8, P479
[7]   Application of continuous-flow liquid phase microextraction to the analysis of phenolic compounds in wastewater samples [J].
Chen, Xinmiao ;
Zhang, Taozhi ;
Liang, Pei ;
Li, Yalan .
MICROCHIMICA ACTA, 2006, 155 (3-4) :415-420
[8]   Optimisation of stir bar sorptive extraction for the analysis of volatile phenols in wines [J].
Díez, J ;
Domínguez, C ;
Guillén, DA ;
Veas, R ;
Barroso, CG .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (02) :263-267
[9]  
*EEC, 1980, 80779EECNOL2291129
[10]   β-Cyclodextrin-bonded silica particles as the solid-phase extraction medium for the determination of phenol compounds in water samples followed by gas chromatography with flame ionization and mass spectrometry detection [J].
Faraji, H .