Susceptibility to hydrogen-induced cracking in H2S corrosion environment of API 5L-X80 weld metal

被引:1
作者
Hilton, J. [1 ]
Fals, H. C. [2 ]
Trevisan, R. E. [1 ]
机构
[1] Univ Estadual Campinas, Fac Engn Mecan, BR-13081970 Campinas, SP, Brazil
[2] Univ Oriente, Fac Ingn Mecan, Santiago De Cuba, Cuba
关键词
Welding; Hydrogen induced cracking; H2S; Cored wire; G-BOP test; ASSISTED CRACKING;
D O I
10.3989/revmetalm.0818
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The susceptibility to hydrogen-induced cracking in H2S environment of welded API X80 steel was Studied. The flux cored arc welding (FCAW) process was employed with E71-T1 and E71-T8K6 wires. The welding parameters were kept constant, but the samples were welded using different preheat temperatures (room temperature and 100 degrees C). The gapped bead-on-plate (G-BOP) test was used. The specimens of modified G-BOP tests were exposed to an environment saturated in H2S, as recommended by the NACE TM0284 standard. The weld beads were characterized by optical microscopy and the level of residual hydrogen in the samples was measured. The fracture surface areas of hydrogen-induced cracking were calculated and the fracture mode was discussed. It was found that the preheating temperature of 100 degrees C was enough to avoid cracking, even in the presence of H2S. It was also found that the E71-T8K6 wire was more susceptible to cracking,and the typical mixed-mode fracture was predominant in all samples
引用
收藏
页码:267 / 276
页数:10
相关论文
共 15 条