Ultrasensitive chemiluminescence immunoassay with enhanced precision for the detection of cTnI amplified by acridinium ester-loaded microspheres and internally calibrated by magnetic fluorescent nanoparticles

被引:104
作者
Zhao, Huan [1 ,2 ]
Lin, Qifeng [2 ]
Huang, Li [1 ,2 ]
Zhai, Yunfeng [1 ,2 ]
Liu, Yuan [1 ]
Deng, Yan [3 ]
Su, Enben [1 ,2 ]
He, Nongyue [1 ,3 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, State Key Lab Bioelect, Natl Demonstrat Ctr Expt Biomed Engn Educ, Nanjing 210096, Peoples R China
[2] Getein Biotechnol Co Ltd, Nanjing 210000, Peoples R China
[3] Hunan Univ Technol, Hunan Key Lab Biomed Nanomat & Devices, Zhuzhou 412007, Peoples R China
关键词
CONTROLLED-RELEASE; TROPONIN-I; EXTRACTION; BEADS; PARTICLES; EXTENSION; DIAGNOSIS; DNA;
D O I
10.1039/d0nr08008j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel enhanced chemiluminescent immunoassay (CLIA) for ultrasensitive and excellent precisive determination of cardiac troponin I (cTnI) was reported. The method made full use of poly[(N-isopropyl acrylamide)-co-(methacrylic acid)] (P(NIPAM-co-MAA)) microspheres as new potential signal enhancers and magnetic fluorescent nanoparticles as internal standards for better precision. This protocol involved a sandwich format, in which the antigen in the sample was captured by the immobilized antibodies on the surface of magnetic fluorescent beads and recognized by the other antibodies labeled with acridinium ester (AE)-loaded P(NIPAM-co-MAA) microspheres. The combination of the remarkable sensitivity of the enhanced CLIA method and the use of P(NIPAM-co-MAA) microspheres as anti-cTnI carriers for acridinium ester signal amplification provided an extremely sensitive limit of blank (LoB) at 0.097 pg mL(-1), a limit of detection (LoD) at 0.116 pg mL(-1), and a limit of quantitation (LoQ) at 0.606 pg mL(-1), much greater than those achieved by the classical chemiluminescence immunoassay (CLIA, Getein). Moreover, the intra-day variable coefficient can be improved to 1.21-2.12%, and inter-day variability was 2.01-3.49% under the application of magnetic fluorescent beads as an internal standard. The sensitivity and precision have reached a high level, comparable with the current commercial detection kits. The results showed a good correlation with a commercial chemiluminescence assay (CLIA, Abbott), with a correlation coefficient of 0.9883. This proposed method has been successfully applied to the clinical determination of cTnI in the human serum.
引用
收藏
页码:3275 / 3284
页数:10
相关论文
共 40 条
[1]   Temperature-sensitive chitosan-poly(N-isopropylacrylamide) interpenetrated networks with enhanced loading capacity and controlled release properties [J].
Alvarez-Lorenzo, C ;
Concheiro, A ;
Dubovik, AS ;
Grinberg, NV ;
Burova, TV ;
Grinberg, VY .
JOURNAL OF CONTROLLED RELEASE, 2005, 102 (03) :629-641
[2]   IFCC educational materials on selected analytical and clinical applications of high sensitivity cardiac troponin assays [J].
Apple, Fred S. ;
Jaffe, Allan S. ;
Collinson, Paul ;
Mockel, Martin ;
Ordonez-Llanos, Jordi ;
Lindahl, Bertil ;
Hollander, Judd ;
Plebani, Mario ;
Than, Martin ;
Chan, M. H. M. .
CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) :201-203
[3]   Advances in Fully Automated Nucleic Acid Extraction System Based on Magnetic Nanobeads [J].
Chen, Zhu ;
Xiao, Changhu ;
Tang, Manling ;
Xu, Yuyue ;
He, Ziyu ;
Hou, Yujing ;
Luo, Xueming ;
Li, Wen ;
Deng, Yan ;
Li, Song .
NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2019, 11 (12) :1633-1643
[4]   Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography [J].
Cho, Il-Hoon ;
Paek, Eui-Hwan ;
Kim, Young-Kee ;
Kim, Joo-Ho ;
Paek, Se-Hwan .
ANALYTICA CHIMICA ACTA, 2009, 632 (02) :247-255
[5]   An on-chip magnetic bead separator using spiral electromagnets with semi-encapsulated permalloy [J].
Choi, JW ;
Liakopoulos, TM ;
Ahn, CH .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) :409-416
[6]   CARDIAC-SPECIFIC TROPONIN-I RADIOIMMUNOASSAY IN THE DIAGNOSIS OF ACUTE MYOCARDIAL-INFARCTION [J].
CUMMINS, B ;
AUCKLAND, ML ;
CUMMINS, P .
AMERICAN HEART JOURNAL, 1987, 113 (06) :1333-1344
[7]   Rapid identification of diarrheagenic Escherichia coli based on barcoded magnetic bead hybridization [J].
Dong, Hongming ;
Tang, Congli ;
He, Ziyu ;
Liu, Hongmei ;
Xu, Yuyue ;
Huang, Hao ;
Yang, Gaojian ;
Xiao, Ziqi ;
Li, Song ;
Deng, Yan ;
Chen, Zhu ;
Chen, Hui ;
Qin, Zuodong ;
Negrin, Yasser Perera ;
He, Nongyue .
CHINESE CHEMICAL LETTERS, 2020, 31 (07) :1812-1816
[8]   Preparation and characterization of pH- and temperature-sensitive pullulan microspheres for controlled release of drugs [J].
Fundueanu, Gheorghe ;
Constantin, Marieta ;
Ascenzi, Paolo .
BIOMATERIALS, 2008, 29 (18) :2767-2775
[9]   The role of troponins in muscle contraction [J].
Gomes, AV ;
Potter, JD ;
Szczesna-Cordary, D .
IUBMB LIFE, 2002, 54 (06) :323-333
[10]   A facile method to synthesize carboxyl-functionalized magnetic polystyrene nanospheres [J].
Guan, Ningning ;
Liu, Chao ;
Sun, Dejun ;
Xu, Jian .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 335 (1-3) :174-180