Feasibility studies with PET detector modules based on an APD array and LSO

被引:0
|
作者
Léonard, SMA [1 ]
Fremout, AAR [1 ]
Wisniewski, D [1 ]
Bruyndonckx, P [1 ]
Tavernier, SPK [1 ]
Wang, YG [1 ]
Fedorov, A [1 ]
机构
[1] Free Univ Brussels, Inter Univ Inst High Energies, B-1050 Brussels, Belgium
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The possibility of extracting depth-of-interaction (DOI) has been studied for block detector configurations, consisting of either a block of LSO or a saw-shaped crystal coupled to a Hamamatsu Si-avalanche photodiode (APD) array 1370. The results of this study, as well as previous results on DOI, obtained with individual crystal configurations consisting of two layers of lutetium oxyorthosilicate (LSO) crystals shifted over half a crystal width with respect to each other, are applied in corrections on the spatial resolution obtained with these Positron Emission Tomography (PET) detector modules. Further improvement in the composition of crystal matrices has been realized. The energy resolution and the light yield for crystals in such a crystal matrix have been evaluated.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Klinikum rechts der Isar der, Technischen Universitaet Muenchen, Muenchen, Germany
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 2): : 1298 - 1302
  • [2] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1649 - 1653
  • [3] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1298 - 1302
  • [4] The LSO/APD array as a possible detector for in-beam PET in hadron therapy
    Kapusta, M
    Crespo, P
    Wolski, D
    Heidel, K
    Heinrich, L
    Hutsch, J
    Pawelke, J
    Sobiella, M
    Trzcinska, A
    Moszynski, M
    Enghardt, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1389 - 1394
  • [5] Spatial resolution and depth-of-interaction studies with a PET detector module composed of LSO and an APD array
    Fremout, AAR
    Chen, RR
    Bruyndonckx, P
    Tavernier, SPK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 131 - 138
  • [6] Performance evaluation of a PET detector module using a continuous LSO scintillator coupled to an APD array
    Léonard, S
    Bruyndonckx, P
    Tavernier, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2160 - 2163
  • [7] First in-beam PET imaging with LSO/APD array detectors
    Crespo, P
    Kapusta, M
    Pawelke, J
    Moszynski, M
    Enghardt, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2654 - 2661
  • [8] First in-beam PET imaging with LSO/APD-array detectors
    Crespo, P
    Kapusta, M
    Pawelke, J
    Moszynski, M
    Enghardt, W
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1904 - 1908
  • [9] Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector
    Spanoudaki, V. C.
    Mann, A. B.
    Otte, A. N.
    Konorov, I.
    Torres-Espallardo, I.
    Paul, S.
    Ziegler, S. I.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [10] Electronics design of a PET detector module with APD array
    Wang, Yong-Gang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (05):