This is a cross-sectional study of the incoming and distal outlet water quality from 41 dental units in Istanbul, carried out to compare the total microbial loads using traditional culture method versus epifluorescence microscopy. The possible presence of Legionella pneumophila using traditional culture method was also analyzed. One hundred and twenty three samples were taken from the high-speed handpiece lines, air-water syringe lines and source (incoming) water supplies from 41 dental units. The samples were assayed for live/dead bacteria, heterotrophic bacterial counts and presence of L. pneumophila bacteria. Thirty nine out of 41 dental units (91%) were not able to meet the standard limit of 200 CFU/ml in dental unit waters. The live bacterial counts were 1-1.5 orders of magnitude higher than aerobic mesophilic heterotrophic bacteria. L. pneumophila (serogroup 2-14) was isolated from five out of 41 units. Some dental units were using commercially bottled (19 l) drinking water as a source. The source water of eight dental unit was heavily contaminated which were fed up by commercially bottled drinking water.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 29 条
[1]   LEGIONELLA CONTAMINATION OF DENTAL-UNIT WATERS [J].
ATLAS, RM ;
WILLIAMS, JF ;
HUNTINGTON, MK .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (04) :1208-1213
[2]   Multiparametric analysis of waterline contamination in dental units [J].
Barbeau, J ;
Tanguay, R ;
Faucher, E ;
Avezard, C ;
Trudel, L ;
Cote, L ;
Prevost, AP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (11) :3954-3959
[3]   Bacterial viability and culturability [J].
Barer, MR ;
Harwood, CR .
ADVANCES IN MICROBIAL PHYSIOLOGY, VOL 41, 1999, 41 :93-137
[4]  
Blake G. C., 1963, Brit. Dent. J., V115, P413
[5]   ISOLATION OF LEGIONELLA SPP FROM ENVIRONMENTAL WATER SAMPLES BY LOW-PH TREATMENT AND USE OF A SELECTIVE MEDIUM [J].
BOPP, CA ;
SUMNER, JW ;
MORRIS, GK ;
WELLS, JG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 13 (04) :714-719
[6]  
BURKE F, 2004, EUROPEAN J ORAL SCI, V112, P412, DOI DOI 10.1111/J.1600-0722.2004.00151.X
[7]  
Cleveland J, 1999, J AM DENT ASSOC, V130, P1653
[8]   The role of manufacturers in reducing biofilms in dental chair waterlines [J].
Coleman, D. C. ;
O'Donnell, M. J. ;
Shore, A. C. ;
Swan, J. ;
Russell, R. J. .
JOURNAL OF DENTISTRY, 2007, 35 (09) :701-711
[9]  
Dennis P., 1988, Isolation of legionellae from environmental specimens. A laboratory manual for Legionella, P31
[10]   THE SOURCE, FREQUENCY AND EXTENT OF BACTERIAL-CONTAMINATION OF DENTAL UNIT WATER-SYSTEMS [J].
FITZGIBBON, EJ ;
BARTZOKAS, CA ;
MARTIN, MV ;
GIBSON, MF ;
GRAHAM, R .
BRITISH DENTAL JOURNAL, 1984, 157 (03) :98-101