Resistance to cyclic fatigue of reciprocating instruments determined at body temperature and phase transformation analysis

被引:18
|
作者
Scott, Raymond [1 ]
Arias, Ana [1 ,2 ]
Macorra, Jose C. [2 ]
Govindjee, Sanjay [3 ]
Peters, Ove A. [1 ,4 ]
机构
[1] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[2] Univ Complutense Madrid, Sch Dent, Dept Conservat Dent & Prothesis, Plaza Ramon 7 Cajal S-N,Ciudad Univ, Madrid 28040, Spain
[3] Univ Calif Berkeley, Dept Civil & Environm Engn, Berkeley, CA 94720 USA
[4] Univ Queensland, Oral Hlth Ctr, Herston, Qld, Australia
关键词
body temperature; cyclic fatigue resistance; differential scanning calorimetry; martensitic transformation temperature; NICKEL-TITANIUM INSTRUMENTS; PROTAPER GOLD; METALLURGICAL CHARACTERIZATION; MECHANICAL-PROPERTIES; ROTARY INSTRUMENTS; WAVEONE; WIRE; DEFECTS; FILES;
D O I
10.1111/aej.12374
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to compare cyclic fatigue (CF) resistance of reciprocating instruments at body temperature and relate the findings to their martensitic transformation temperatures. Contemporary nickel-titanium (NiTi) reciprocating instruments WaveOne Primary, WaveOne Gold Primary and EdgeFile X1 (n = 20 each and #25 tip diameter) were tested for CF resistance at body temperature (37 +/- 1 degrees C). Instruments were actioned according to manufacturer guidelines until fracture occurred in a simulated canal (angle of curvature = 60 degrees, radius of curvature = 3 mm and centre of curvature = 5 mm from the tip). Time to fracture was recorded, and data analysed using Weibull analysis. Two instruments of each were tested using differential scanning calorimetry (DSC) to assess phase transformation temperatures. Reciprocating instruments manufactured with new alloys seem to be safer to CF than those manufactured with traditional M-Wire at body temperature. Martensitic transformation temperatures seem not to relate with fatigue behaviour for reciprocating motions.
引用
收藏
页码:400 / 406
页数:7
相关论文
共 50 条
  • [21] Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments
    Elnaghy, A. M.
    Elsaka, S. E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (10) : 991 - 998
  • [22] Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments
    Nogueira Leal Silva, Emmanuel Joao
    Leal Vieira, Victor Talarico
    Hecksher, Fernanda
    Silva dos Santos Oliveira, Marja Ribeiro
    Antunes, Henrique dos Santos
    Lima Moreira, Edson Jorge
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (07) : 2633 - 2638
  • [23] Dynamic Cyclic Fatigue Resistance of Heat-treated Nickel Titanium Instruments in Reciprocating Motion
    Sobral, Thais Kauana Magalhaes
    Piasecki, Lucila
    Tomazinho, Flavia Sens Fagundes
    Kirchhoff, Alison Luis
    Gabardo, Marilisa Carneiro Leao
    Mattos, Natanael Henrique Ribeiro
    Filho, Flares Baratto
    Fariniuk, Luiz Fernando
    EUROPEAN ENDODONTIC JOURNAL, 2023, 8 (03): : 201 - 206
  • [24] Cyclic Fatigue Resistance of 3 Different Nickel-Titanium Reciprocating Instruments in Artificial Canals
    Higuera, Oscar
    Plotino, Gianluca
    Tocci, Luigi
    Carrillo, Gabriela
    Gambarini, Gianluca
    Jaramillo, David E.
    JOURNAL OF ENDODONTICS, 2015, 41 (06) : 913 - 915
  • [25] Cyclic Fatigue and Torsional Resistance of Four Martensite-Based Nickel Titanium Reciprocating Instruments
    Silva, Emmanuel J. N. L.
    Lima, Carolina O.
    Vieira, Victor T. L.
    Antunes, Henrique S.
    Moreira, Edson J. L.
    Versiani, Marco A.
    EUROPEAN ENDODONTIC JOURNAL, 2020, 5 (03): : 231 - 235
  • [26] Cyclic Fatigue Resistance of Nickel-Titanium Reciprocating Instruments after Simulated Clinical Use
    Duque, Jussaro Alves
    Bramante, Clovis Monteiro
    Hungaro Duarte, Marco Antonio
    Alcalde, Murilo Priori
    Nogueira Leal Silva, Emmanuel Joao
    Vivan, Rodrigo Ricci
    JOURNAL OF ENDODONTICS, 2020, 46 (11) : 1771 - 1775
  • [27] Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments
    Emmanuel João Nogueira Leal Silva
    Victor Talarico Leal Vieira
    Fernanda Hecksher
    Marja Ribeiro Silva dos Santos Oliveira
    Henrique dos Santos Antunes
    Edson Jorge Lima Moreira
    Clinical Oral Investigations, 2018, 22 : 2633 - 2638
  • [28] Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion
    Gambarini, G.
    Gergi, R.
    Naaman, A.
    Osta, N.
    Al Sudani, D.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (09) : 802 - 806
  • [29] Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel-titanium single-file rotary and reciprocating instruments at body temperature
    Erik, Cevat Emre
    Ozyurek, Taha
    ODONTOLOGY, 2019, 107 (02) : 190 - 195
  • [30] A laboratory study analysis of the cyclic fatigue strength of glide path instruments at simulated body temperature
    Fontana, Carlos Eduardo
    Bonfante, Luisa
    Rosa, Yara Maria
    Mendonca de Moura, Joao Daniel
    Pelegrine, Rina Andrea
    Pedro Rocha, Daniel Guimaraes
    De Martine, Alexandre Sigrist
    Pinheiro, Sergio Luiz
    da Silveira Bueno, Carlos Eduardo
    GIORNALE ITALIANO DI ENDODONZIA, 2022, 36 (02): : 39 - 47