Estimation of Local Relative Humidity in Cathode Catalyst Layers of PEMFC

被引:3
作者
Gazzarri, Javier [1 ]
Xia, Zetao [1 ]
Zhao, Xinsheng [1 ]
Wang, Qianpu [1 ]
Eikerling, Michael [2 ]
Liu, Simon [1 ]
Xie, Zhong [1 ]
机构
[1] Inst Fuel Cell Innovat, Natl Res Council, 4250 Wesbrook Mall, Vancouver, BC V6T 1W5, Canada
[2] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
来源
PROTON EXCHANGE MEMBRANE FUEL CELLS 9 | 2009年 / 25卷 / 01期
关键词
ELECTROCHEMICAL IMPEDANCE;
D O I
10.1149/1.3210675
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A method is presented to estimate the local relative humidity in cathode catalyst layers of PEM fuel cells. Based on impedance measurements under different experimental conditions, this technique allows the estimation of an average value for relative humidity using a correlation with the catalyst layer effective proton resistance. A fully humidified anode was found to increase the relative humidity of the nominally drier cathode because of water permeation through the membrane, to as much as almost 70% for a nominal 30% when the anode RH was held at 100%.
引用
收藏
页码:1203 / 1210
页数:8
相关论文
共 2 条
[1]   Electrochemical impedance of the cathode catalyst layer in polymer electrolyte fuel cells [J].
Eikerling, M ;
Kornyshev, AA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 475 (02) :107-123
[2]   Measurement of catalyst layer electrolyte resistance in PEFCs using electrochemical impedance spectroscopy [J].
Makharia, R ;
Mathias, MF ;
Baker, DR .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (05) :A970-A977