A New Spectra Transfer Method for Multivariate Calibration Model of Molecular Spectroscopy Analysis

被引:2
作者
Cao Yu-ting
Yuan Hong-fu
Zhao Zhong
机构
[1] College of Information Science and Technology, Beijing University of Chemical Technology, Beijing
[2] College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing
关键词
NIR spectroscopy; MIR spectroscopy; Spectra transfer; Piecewise direct standardization; Spectral angle; NIR; STANDARDIZATION; IMPROVEMENT;
D O I
10.3964/j.issn.1000-0593(2018)03-0973-09
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Whether it is for near-infrared (NIR) spectra or mid-infrared (MIR) spectra, the issue of multivariate calibration model transfer between spectrometers has not been satisfactorily solved yet. To realize the sharing of model or spectra between the spectrometers, an improved piecewise direct standardization (PDS) method, Spectra-Angle-PDS (SA-PDS), is proposed in this work. Spectral angle (SA) measurement which can evaluate the similarity between spectra or the difference between the spectral vector and the shape of the spectral curve is used as a criterion for optimization of parameters of PDS. The model transfer no longer needs reference data so that the model transfer is not affected by the error of properties of validation samples and the model. The model transfer from master spectrometer to slave one or opposite on the contrary can be more easily realized with SA-PDS. The proposed spectra transfer method (SA-PDS) has been applied to predict the content of glycosides in tobacco and the content of wax in asphalt using NIR and MIR spectra respectively. The PDS method using RMSEP to select parameters has also been performed for comparative study of the proposed model transfer technique. For the spectra transfer from salve to master spectrometers of NIR, comparative experiment results have shown that the root-mean-square error of prediction (RMSEP)with the proposed SA-PDS method is reduced from 5.257 4 (before transfer) to 1.337 1 (after transfer), and much smaller than that with PDS method (1.350 3). For the spectra transfer from salve to master spectrometers of MIR, the precision of model transfer also improved significantly, accompanied by the reduction in RMSEP from 0.525 1 to 0.186 9, is proven to be better than that with PDS method (0.219 4). The satisfactory spectra transfer results with the proposed SA-PDS method from the master spectrometer to the slave spectrometer has also been verified.
引用
收藏
页码:973 / 981
页数:9
相关论文
共 18 条
  • [1] Batten GD, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P105
  • [2] Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration
    Bouveresse, E
    Massart, DL
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) : 201 - 213
  • [3] Application of standardisation methods to correct the spectral differences induced by a fibre optic probe used for the near-infrared analysis of pharmaceutical tablets
    Bouveresse, E
    Casolino, C
    de la Pezuela, C
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) : 35 - 42
  • [4] Systematic prediction error correction: A novel strategy for maintaining the predictive abilities of multivariate calibration models
    Chen, Zeng-Ping
    Li, Li-Mei
    Yu, Ru-Qin
    Littlejohn, David
    Nordon, Alison
    Morris, Julian
    Dann, Alison S.
    Jeffkins, Paul A.
    Richardson, Mark D.
    Stimpson, Sarah L.
    [J]. ANALYST, 2011, 136 (01) : 98 - 106
  • [5] Camtracker: a new camera controlled high precision solar tracker system for FTIR-spectrometers
    Gisi, M.
    Hase, F.
    Dohe, S.
    Blumenstock, T.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2011, 4 (01) : 47 - 54
  • [6] THE EFFECT OF MULTIPLICATIVE SCATTER CORRECTION (MSC) AND LINEARITY IMPROVEMENT IN NIR SPECTROSCOPY
    ISAKSSON, T
    NAES, T
    [J]. APPLIED SPECTROSCOPY, 1988, 42 (07) : 1273 - 1284
  • [7] A new multivariate calibration model transfer method of near-infrared spectral analysis
    Liang, Chen
    Yuan, Hong-fu
    Zhao, Zhong
    Song, Chun-feng
    Wang, Jia-jun
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2016, 153 : 51 - 57
  • [8] OSBORNE BG, 1983, J FOOD TECHNOL, V18, P453, DOI 10.1177/0047117804048489
  • [9] NIR fingerprint screening for early control of non-conformity at feed mills
    Pierna, Juan Antonio Fernandez
    Abbas, Ouissam
    Lecler, Bernard
    Hogrel, Patrick
    Dardenne, Pierre
    Baeten, Vincent
    [J]. FOOD CHEMISTRY, 2015, 189 : 2 - 12
  • [10] Near-infrared spectroscopic prediction of chemical composition of a series of petrochemical process streams for aromatics production
    Reboucas, Marcio V.
    dos Santos, Jamile Batista
    Domingos, Daniela
    Massa, Ana Rosa C. G.
    [J]. VIBRATIONAL SPECTROSCOPY, 2010, 52 (01) : 97 - 102