Revised amplitude modulation for contrast-enhanced ultrasound imaging with a cMUT array.

被引:1
作者
Fouan, Damien [1 ]
Bouakaz, Ayache [1 ]
机构
[1] Univ Tours, INSERM, U930, Imagerie & Cerveau, Tours, France
来源
2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2015年
关键词
cMUT; Microbubbles; Contrast sequences; Nonlinear acoustic; TRANSDUCERS; AGENTS;
D O I
10.1109/ULTSYM.2015.0231
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Over the past 15 years, capacitive micro-machined ultrasonic transducers (cMUT) have been developed as a promising alternative to standard piezoelectric transducer (PZT). A large bandwidth and a reduction in self-heating are among the main advantages of this high potential technology but it suffers from a high intrinsic nonlinearity. This behavior could lead to misclassification of tissue in ultrasound contrast-enhanced imaging. Classical sequences, such as Pulse Inversion (PI) or Amplitude Modulation (AM) are no longer suitable and the only solution seems to be the compensation of the cMUT nonlinearity by sending a pre-compensated waveform. In this work, we show that an alternative sequence to amplitude modulation mode (already used with PZT arrays) can be successfully applied with a cMUT probe without any limitation related to the nonlinearity of the transmitter.
引用
收藏
页数:4
相关论文
共 12 条
[1]   Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging [J].
Degertekin, FL ;
Guldiken, RO ;
Karaman, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) :474-482
[2]   Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power [J].
Eckersley, RJ ;
Chin, CT ;
Burns, PN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (02) :213-219
[3]  
George A. B.-F., 1996, MEANS INCREASING SEN
[4]   Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers [J].
Huang, Yongli ;
Haeggstrom, Edward ;
Bayram, Baris ;
Zhuang, Xuefeng ;
Ergun, Arif Sanh ;
Cheng, Ching-Hsiang ;
Khuri-Yakub, Butrus T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (10) :1918-1933
[5]  
Lohfink A, 2005, ULTRASON, P585
[6]   Evaluation of bias voltage modulation sequence for nonlinear contrast agent imaging using a capacitive micromachined ultrasonic transducer array [J].
Novell, Anthony ;
Legros, Mathieu ;
Gregoire, Jean-Marc ;
Dayton, Paul A. ;
Bouakaz, Ayache .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (17) :4879-4896
[7]   Exploitation of Capacitive Micromachined Transducers for Nonlinear Ultrasound Imaging [J].
Novell, Anthony ;
Legros, Mathieu ;
Felix, Nicolas ;
Bouakaz, Ayache .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (12) :2733-2743
[8]   Pulse inversion Doppler: A new method for detecting nonlinear echoes from microbubble contrast agents [J].
Simpson, DH ;
Chin, CT ;
Burns, PN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (02) :372-382
[9]   EFFECTS OF NONLINEAR PROPAGATION IN ULTRASOUND CONTRAST AGENT IMAGING [J].
Tang, Meng-Xing ;
Kamiyama, Naohisa ;
Eckersley, Robert J. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (03) :459-466
[10]   Feasibility of MR-temperature mapping of ultrasonic heating from a CMUT [J].
Wong, Serena H. ;
Watkins, Ronald D. ;
Kupnik, Mario ;
Pauly, Kim Butts ;
Khuri-Yakub, Butrus T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (04) :811-818