Validation of Accuracy of Three-Dimensional Left Atrial CartoSound and CT Image Integration: Influence of Respiratory Phase and Cardiac Cycle

被引:15
作者
Kimura, Masaomi [1 ]
Sasaki, Shingo [1 ]
Owada, Shingen [1 ]
Horiuchi, Daisuke [1 ]
Sasaki, Kenichi [1 ]
Itoh, Taihei [1 ]
Ishida, Yuji [1 ]
Kinjo, Takahiko [1 ]
Okumura, Ken [1 ]
机构
[1] Hirosaki Univ, Grad Sch Med, Dept Cardiol, Hirosaki, Aomori 0368562, Japan
关键词
atrial fibrillation; CartoSound; catheter ablation; computed tomography; image integration; intracardiac echocardiography; ELECTROANATOMIC MAPPING SYSTEM; CATHETER ABLATION; FIBRILLATION; ULTRASOUND; IMPACT;
D O I
10.1111/jce.12170
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
CartoSound Merge Using Left Atrial Posterior Wall. Background: CartoSound (TM) (CS) module is useful in integrating 3-dimensional (3D) left atrial (LA) image with CT image. Integration method, however, has not been established. We reported the accuracy of LA electroanatomical (EA) and CT image integration by registering LA roof (LAR) and posterior wall (LAPW). Methods: The consecutive 56 atrial fibrillation patients undergoing pulmonary vein isolation were studied. In the initial 29 patients, before the transseptal puncture, 3D CS LAR and LAPW image was created by registering a mean of 10 contour lines between the right and left pulmonary veins. After transseptally inserting a mapping catheter into LA, 3D EA image of LAR and LAPW was obtained by sampling a mean of 40 points. LA CT image was taken at the full-inspiratory position and 0% of R-R interval. After visual alignment of CS or EA and LA CT image, the 2 images were integrated with surface registration program. In the latter 27 patients, both CT and CS images were taken while matching the respiratory phase at the end-tidal position and cardiac cycle at 50% of R-R interval. Results: In the initial 29 patients, the mean distances between EA and CT images and between CS and CT images were 1.53 +/- 0.27 and 1.59 +/- 0.23 mm, respectively (P = NS). In the latter 27, the mean distance was decreased to 1.08 +/- 0.14 mm (P < 0.0001). Conclusions: CS system is useful in image integration with 3D CT. Matching both respiratory phase and cardiac cycle between CS and CT image acquisition improves the image integration accuracy.
引用
收藏
页码:1002 / 1007
页数:6
相关论文
共 9 条
[1]   Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system: Validation of a registration method [J].
Bertaglia, Emanuele ;
Brandolino, Glauco ;
Zoppo, Franco ;
Zerbo, Francesca ;
Pascotto, Pietro .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (03) :273-282
[2]   Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge™ Italian Registry [J].
Bertaglia, Emanuele ;
Della Bella, Paolo ;
Tondo, Claudio ;
Proclemer, Alessandro ;
Bottoni, Nicola ;
De Ponti, Roberto ;
Landolina, Maurizio ;
Bongiorni, Maria Grazia ;
Coro, Leonardo ;
Stabile, Giuseppe ;
Dello Russo, Antonio ;
Verlato, Roberto ;
Mantica, Massimo ;
Zoppo, Franco .
EUROPACE, 2009, 11 (08) :1004-1010
[3]   Changes in left atrial anatomy due to respiration:: Impact on three-dimensional image integration during atrial fibrillation ablation [J].
Ector, Joris ;
De Buck, Stijn ;
Loeckx, Dirk ;
Coudyzer, Walter ;
Maes, Frederik ;
Dymarkowski, Steven ;
Bogaert, Jan ;
Heidbuchelel, Hein .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (08) :828-834
[4]   Three-dimensional cardiac image integration of electroanatomical mapping of only left atrial posterior wall with CT image to guide circumferential pulmonary vein ablation [J].
Itoh, Taihei ;
Sasaki, Shingo ;
Kimura, Masaomi ;
Owada, Shingen ;
Horiuchi, Daisuke ;
Sasaki, Kenichi ;
Okumura, Ken .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (03) :167-173
[5]   Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation [J].
Kistler, PM ;
Earley, MJ ;
Harris, S ;
Abrams, D ;
Ellis, S ;
Sporton, SC ;
Schilling, RJ .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (04) :341-348
[6]   Impact of Image Integration on Catheter Ablation for Atrial Fibrillation Using Three-Dimensional Electroanatomic Mapping: A Meta-Analysis [J].
Liu, Shan-Xin ;
Zhang, Yu ;
Zhang, Xing-Wei .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (10) :1242-1247
[7]   Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation [J].
Mikaelian, BJ ;
Malchano, ZJ ;
Neuzil, P ;
Weichet, J ;
Doshi, SK ;
Ruskin, JN ;
Reddy, VY .
CIRCULATION, 2005, 112 (02) :E35-E36
[8]   Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention Methods, Quantitative Validation, and Clinical Feasibility of a Novel Multimodality Image Mapping System [J].
Okumura, Yasuo ;
Henz, Benhur D. ;
Johnson, Susan B. ;
Bunch, T. Jared ;
O'Brien, Christine J. ;
Hodge, David O. ;
Altman, Andres ;
Govari, Assaf ;
Packer, Douglas L. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2008, 1 (02) :110-119
[9]   New generation of electro-anatomic mapping: full intracardiac ultrasound image integration [J].
Packer, Douglas L. ;
Johnson, Susan B. ;
Kolasa, Mark W. ;
Bunch, Thomas J. ;
Henz, Benhur D. ;
Okumura, Yasuo .
EUROPACE, 2008, 10 :35-41