The influence of nasal abnormalities in adherence to continuous positive airway pressure device therapy in obstructive sleep apnea patients

被引:8
作者
Martinho Haddad, Fernanda Louise [1 ,2 ]
Vidigal, Tatiana de Aguiar [2 ]
Mello-Fujita, Luciane [1 ]
Cintra, Fatima Dumas [1 ]
Gregorio, Luiz Carlos [2 ]
Tufik, Sergio [1 ]
Bittencourt, Lia [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Psicobiol, Disciplina Med & Biol Sono, BR-04024002 Sao Paulo, Brazil
[2] Univ Fed Sao Paulo, Dept Otorrinolaringol & Cirurgia Cabeca & Pescoco, BR-04024002 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Acoustic rhinometry; Nasofibroscopy; Nasal inspiratory peak flow; Nasal obstruction; Obstructive sleep apnea; Upper airway; RESISTANCE; SURGERY;
D O I
10.1007/s11325-013-0824-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The few studies that examine the effect of nasal abnormalities on continuous positive airway pressure device (CPAP) adherence are controversial. The aim of this study was to evaluate the contribution of nasal abnormalities in CPAP adherence. We included patients with moderate to severe OSA. The patients were submitted to rhinoscopy, nasofibroscopy, nasal inspiratory peak flow, and acoustic rhinometry. The patients who used a CPAP for 4 h or more per night for at least 70 % of the nights over a 6-month period were considered to have good adherence. Thirty-four patients finished the study. Eleven (33.4 %) were female and 23 (67.6 %) were male. Sixteen (47.1 %) patients had good adherence. The body mass index (p = 0.030), neck circumference (p = 0.006), and apnea-hypopnea index (p = 0.032) were higher, and the oxyhemoglobin saturation minimum was lower (p = 0.041) in the good adherence group. Nasal parameters showed no differences between good and poor adherence groups. In Spearman's correlation, surprisingly, there was a negative correlation between the highest number of hours of CPAP use with smaller values of nasal minimal cross-sectional areas in the supine position (r, 0.375; p = 0.029). In the linear regression model, the nasal findings that predicted increased of the CPAP use were the following: lower scores of nasal symptoms (p = 0.007) and lower nasal volume in supine position (p = 0.001). The majority of the nasal parameters evaluated in this study did not influence CPAP adherence.
引用
收藏
页码:1201 / 1207
页数:7
相关论文
共 22 条
  • [1] [Anonymous], 2005, International Classification of Sleep Disorders, V2nd
  • [2] Portuguese-language version of the Epworth sleepiness scale: validation for use in Brazil
    Bertolazi, Alessandra Naimaier
    Fagondes, Simone Chaves
    Hoff, Leonardo Santos
    Pedro, Vinicius Dallagasperina
    Menna Barreto, Sergio Saldanha
    Johns, Murray W.
    [J]. JORNAL BRASILEIRO DE PNEUMOLOGIA, 2009, 35 (09) : 877 - 883
  • [3] BONNET MH, 1992, SLEEP, V15, P526
  • [4] Impact of upper airway surgery on CPAP compliance in difficult-to-manage obstructive sleep apnea
    Chandrashekariah, Ranju
    Shaman, Ziad
    Auckley, Dennis
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2008, 134 (09) : 926 - 930
  • [5] Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research
    Flemons, WW
    Buysse, D
    Redline, S
    Pack, A
    Strohl, K
    Wheatley, J
    Young, T
    Douglas, N
    Levy, P
    McNicholas, W
    Fleetham, J
    White, D
    Schmidt-Nowarra, W
    Carley, D
    Romaniuk, J
    [J]. SLEEP, 1999, 22 (05) : 667 - 689
  • [6] Obstructive Sleep Apnea and Cardiovascular Disease
    Kato, Masahiko
    Adachi, Taro
    Koshino, Yuki
    Somers, Virend K.
    [J]. CIRCULATION JOURNAL, 2009, 73 (08) : 1363 - 1370
  • [7] Predictors of long-term compliance with continuous positive airway pressure
    Kohler, Malcolm
    Smith, Debbie
    Tippett, Victoria
    Stradling, John R.
    [J]. THORAX, 2010, 65 (09) : 829 - 832
  • [8] Long-term compliance with CPAP therapy in obstructive sleep apnea patients and in snorers
    Krieger, J
    Kurtz, D
    Petiau, C
    Sforza, E
    Trautmann, D
    [J]. SLEEP, 1996, 19 (09) : S136 - S143
  • [9] Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders
    Kushida, Clete A.
    Littner, Michael R.
    Hirshkowitz, Max
    Morgenthaler, Timothy I.
    Alessi, Cathy A.
    Bailey, Dennis
    Boehlecke, Brian
    Brown, Terry M.
    Coleman, Jack, Jr.
    Friedman, Leah
    Kapen, Sheldon
    Kapur, Vishesh K.
    Kramer, Milton
    Lee-Chiong, Teofilo
    Owens, Judith
    Pancer, Jeffrey P.
    Swick, Todd J.
    Wise, Merrill S.
    [J]. SLEEP, 2006, 29 (03) : 375 - 380
  • [10] Comparison of anatomic, physiological, and subjective measures of the nasal airway
    Lam, Derek J.
    James, Kathryn T.
    Weaver, Edward M.
    [J]. AMERICAN JOURNAL OF RHINOLOGY, 2006, 20 (05): : 463 - 470