Comparison of ultra-high-resolution parallel-hole collimator materials based on the CdTe pixelated semiconductor SPECT system

被引:25
|
作者
Lee, Young-Jin [1 ]
Ryu, Hyun-Ju [1 ]
Lee, Seung-Wan [1 ]
Park, Su-Jin [1 ]
Kim, Hee-Joung [1 ]
机构
[1] Yonsei Univ, Coll Hlth Sci, Dept Radiol Sci, Wonju 220710, Gangwon Do, South Korea
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2013年 / 713卷
基金
新加坡国家研究基金会;
关键词
SPECT; Cadmium telluride (CdTe) pixelated semiconductor detector; Ultra-high-resolution parallel-hole collimator materials; Monte Carlo simulation; MONTE-CARLO SIMULATIONS; GAMMA-CAMERA; PINHOLE SPECT; GATE; PERFORMANCE; TOMOGRAPHY; VALIDATION; DESIGN; IMAGER;
D O I
10.1016/j.nima.2013.03.014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recently, many studies have sought to improve the sensitivity and spatial resolution of pixelated semiconductor detectors. Spatial resolution can be improved by using a pinhole or pixelated parallel-hole collimator with equal hole and pixel sizes. We compared a pinhole to a pixelated parallel-hole collimator and found that the pixelated parallel-hole collimator had higher sensitivity. Additionally, collimator materials with high absorption efficiency are often used because of their high spatial resolution. The purpose of this study was to compare the quality of images generated using a pixelated semiconductor single photon emission computed tomography (SPECT) system simulated with pixelated parallel-hole collimators of lead, tungsten, gold, and depleted uranium. We performed a simulation study of the PID 350 (Ajat Oy Ltd., Finland) CdTe pixelated semiconductor detector, which consists of small pixels (0.35 x 0.35 mm(2)), using a Geant4 Application for Tomographic Emission (GATE) simulation. Sensitivities and spatial resolutions were measured for the four collimator materials. To evaluate overall image performance, a hot-rod phantom was designed using GATE simulation. The results showed that with lead, sensitivity was 425%, 6.53%, and 1028% higher than with tungsten, gold, and depleted uranium, respectively. Spatial resolution using depleted uranium was 3.19%, 4.19%, and 8.01% better than that of gold, tungsten, and lead, respectively. Sensitivity and spatial resolution showed little difference among the four types of collimator materials tested. It was difficult to visually distinguish between the reconstructed images of the hot-rod phantom for different collimator materials. The results are promising for notable cost reductions in collimator manufacturing while avoiding impractical and rare materials. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [1] Optimization of an ultra-high-resolution parallel-hole collimator for CdTe semiconductor SPECT system
    Lee, Y. -J.
    Ryu, H. -J.
    Cho, H. -M.
    Lee, S. -W.
    Choi, Y. -N.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [2] A Monte Carlo simulation study of the feasibility of a high resolution parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Lee, Y. -J.
    Park, S. -J.
    Lee, S. -W.
    Kim, D. -H.
    Kim, Y. -S.
    Jo, B. -D.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [3] Monte carlo simulation study of a novel parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Kim, Dae-Hong
    Rhee, Yong-Chun
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (11) : 1737 - 1744
  • [4] Monte carlo simulation study of a novel parallel-hole collimator with a CdTe pixelated semiconductor SPECT system
    Young-Jin Lee
    Dae-Hong Kim
    Yong-Chun Rhee
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 1737 - 1744
  • [5] The Effect of High-resolution Parallel-hole Collimator Materials with a Pixelated Semiconductor SPECT System at Equivalent Sensitivities: Monte Carlo Simulation Studies
    Lee, Young-Jin
    Kim, Dae-Hong
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 1055 - 1062
  • [6] The effect of high-resolution parallel-hole collimator materials with a pixelated semiconductor SPECT system at equivalent sensitivities: Monte Carlo simulation studies
    Young-Jin Lee
    Dae-Hong Kim
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2014, 64 : 1055 - 1062
  • [7] Optimization using detective quantum efficiency (DQE) of the high-resolution parallel-hole collimators with CdTe pixelated semiconductor SPECT system
    Lee, Young-Jin
    Kim, Dae-Hong
    Kim, Ye-seul
    Kim, Hee-Joung
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [8] Optimization of the SPECT systems based on a CdTe pixelated semiconductor detector using novel parallel-hole collimators
    Lee, Y. -J.
    Park, S. -J.
    Kim, D. -H.
    Kim, H. -J.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [9] Experimental Study of an Easily Controlled Ultra-High-Resolution Pixel-Matched Parallel-Hole Collimator with a Small Cadmium Zinc Telluride Pixelated Gamma Camera System
    Lee, Seungwan
    Kim, Hee-Joung
    Bae, Se Young
    Lee, Youngjin
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (03) : 276 - 282
  • [10] Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
    Sadremomtaz, Alireza
    Telikani, Zeinab
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2016, 24 (02): : 136 - 143