Experimental research on the dynamic instability characteristic of a pressure relief valve

被引:19
作者
Ma, Wei [1 ]
Ma, Fei [2 ]
Guo, Rong [2 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Resource Engn, 30 Xueyuan Rd, Beijing 100083, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Mech Engn, Beijing, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Pressure relief valve; dynamic instability; flutter; chatter; stable boundary; FLUID-STRUCTURE INTERACTION; CFD ANALYSIS; VAPOR; VIBRATIONS;
D O I
10.1177/1687814019833531
中图分类号
O414.1 [热力学];
学科分类号
摘要
This article presents detailed experimental results of the influencing factors of flow rate, set pressure, and inlet pipe length of a pressure relief valve. In order to analyze the influence of different flow rates on the instability characteristics of pressure relief valve, the multi-stage output of pump flow is realized. In terms of modeling, we investigated the theory concerning instability in the system: the 3% rule boundary. Data analyses on typical stable, cycling, and chatter instability conditions are conducted. The stable boundaries of the 3% rule and the quarter-wave model are drawn, which are consistent with the experimental results.
引用
收藏
页数:13
相关论文
共 27 条
[1]   The dynamic response of pressure relief valves in vapor or gas service. Part II: Experimental investigation [J].
Aldeeb, A. A. ;
Darby, Ron ;
Arndt, Scott .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2014, 31 :127-132
[2]  
Bazso C., 2015, PERIOD POLYTECH-MECH, V59, P1
[3]   CFD analysis with fluid-structure interaction of opening high-pressure safety valves [J].
Beune, A. ;
Kuerten, J. G. M. ;
van Heumen, M. P. C. .
COMPUTERS & FLUIDS, 2012, 64 :108-116
[4]   Analysis of flow-induced instability in a redesigned steam control valve [J].
Bolin, Chris ;
Engeda, Abraham .
APPLIED THERMAL ENGINEERING, 2015, 83 :40-47
[5]  
[陈晋市 Chen Jinshi], 2016, [吉林大学学报. 工学版, Journal of Jilin University. Engineering and Technology Edition], V46, P465
[6]   The dynamic response of pressure relief valves in vapor or gas service. Part III: Model validation [J].
Darby, Ron ;
Aldeeb, A. A. .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2014, 31 :133-141
[7]   The dynamic response of pressure relief valves in vapor or gas service, part I: Mathematical model [J].
Darby, Ron .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2013, 26 (06) :1262-1268
[8]  
Du HuiYong Du HuiYong, 2015, Transactions of the Chinese Society of Agricultural Engineering, V31, P71
[9]  
Du X, 2016, J CHIN AGR MECH, V37, P129
[10]   Analysis of pressure oscillations and safety relief valve vibrations in the main steam system of a Boiling Water Reactor [J].
Galbally, David ;
Garcia, Gonzalo ;
Hernando, Jesus ;
Sanchez, Juan de Dios ;
Barral, Marcos .
NUCLEAR ENGINEERING AND DESIGN, 2015, 293 :258-271