Effect of respiratory motion on cardiac defect contrast in myocardial perfusion SPECT: a physical phantom study

被引:5
作者
Kortelainen, Matti J. [1 ,2 ]
Koivumaki, Tuomas M. [3 ]
Vauhkonen, Marko J. [1 ]
Hakulinen, Mikko A. [1 ,2 ]
机构
[1] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[2] Kuopio Univ Hosp, Diagnost Imaging Ctr, Kuopio, Finland
[3] Cent Finland Cent Hosp, Dept Radiat Therapy, Jyvaskyla, Finland
基金
芬兰科学院;
关键词
SPECT; Myocardial perfusion imaging; Respiratory motion; Phantom; POSITRON-EMISSION-TOMOGRAPHY; ORDERED-SUBSETS; PET; RECONSTRUCTION; HEART; RESOLUTION; 3D;
D O I
10.1007/s12149-019-01335-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveCorrection for respiratory motion in myocardial perfusion imaging requires sorting of emission data into respiratory windows where the intra-window motion is assumed to be negligible. However, it is unclear how much intra-window motion is acceptable. The aim of this study was to determine an optimal value of intra-window residual motion.MethodsA custom-designed cardiac phantom was created and imaged with a standard dual-detector SPECT/CT system using Tc-99m as the radionuclide. Projection images were generated from the list-mode data simulating respiratory motion blur of several magnitudes from 0 (stationary phantom) to 20mm. Cardiac defect contrasts in six anatomically different locations, as well as myocardial perfusion of apex, anterior, inferior, septal and lateral walls, were measured at each motion magnitude. Stationary phantom data were compared to motion-blurred data. Two physicians viewed the images and evaluated differences in cardiac defect visibility and myocardial perfusion.ResultsSignificant associations were observed between myocardial perfusion in the anterior and inferior walls and respiratory motion. Defect contrasts were found to decline as a function of motion, but the magnitude of the decline depended on the location and shape of the defect. Defects located near the cardiac apex lost contrast more rapidly than those located on the anterior, inferior, septal and lateral wall. The contrast decreased by less than 5% at every location when the motion magnitude was 2mm or less. According to a visual evaluation, there were differences in myocardial perfusion if the magnitude of the motion was greater than 1mm, and there were differences in the visibility of the cardiac defect if the magnitude of the motion was greater than 9mm.ConclusionsIntra-window respiratory motion should be limited to 2mm to effectively correct for respiratory motion blur in myocardial perfusion SPECT.
引用
收藏
页码:305 / 316
页数:12
相关论文
共 40 条
[1]   A generalized model for the conversion from CT numbers to linear attenuation coefficients [J].
Bai, CY ;
Shao, L ;
Da Silva, AJ ;
Zhao, Z .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1510-1515
[2]   Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation Map [J].
Bousse, Alexandre ;
Bertolli, Ottavia ;
Atkinson, David ;
Arridge, Simon ;
Ourselin, Sebastien ;
Hutton, Brian F. ;
Thielemans, Kris .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) :217-228
[3]   Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT [J].
Brambilla, M ;
Cannillo, B ;
Dominietto, M ;
Leva, L ;
Secco, C ;
Inglese, E .
ANNALS OF NUCLEAR MEDICINE, 2005, 19 (02) :75-82
[4]   End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system [J].
Chan, Chung ;
Harris, Mark ;
Le, Max ;
Biondi, James ;
Grobshtein, Yariv ;
Liu, Yi-Hwa ;
Sinusas, Albert J. ;
Liu, Chi .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (20) :6267-6287
[5]  
Cherry SR, 2003, PHYS NUCL MED, P239
[6]   Development of respiratory gated myocardial SPECT system [J].
Cho, K ;
Kumiata, S ;
Okada, S ;
Kumazaki, T .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (01) :20-28
[7]   Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study [J].
Daou, Doumit ;
Sabbah, Remy ;
Coaguila, Carlos ;
Boulahdour, Hatem .
JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (05) :1598-1607
[8]   Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes [J].
Dawood, Mohammad ;
Buether, Florian ;
Lang, Norbert ;
Schober, Otmar ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2007, 34 (07) :3067-3076
[9]   Optimal number of respiratory gates in positron emission tomography: A cardiac patient study [J].
Dawood, Mohammad ;
Buether, Florian ;
Stegger, Lars ;
Jiang, Xiaoyi ;
Schober, Otmar ;
Schaefers, Michael ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2009, 36 (05) :1775-1784
[10]   Estimation and correction of cardiac respiratory motion in SPECT in the presence of limited-angle effects due to irregular respiration [J].
Dey, Joyoni ;
Segars, William P. ;
Pretorius, P. Hendrik ;
Walvick, Ronn P. ;
Bruyant, Philippe P. ;
Dahlberg, Seth ;
King, Michael A. .
MEDICAL PHYSICS, 2010, 37 (12) :6453-6465