Assessing metabolic rate and indoor air quality with passive environmental sensors

被引:19
作者
Ruiz, Ivan [1 ]
Sprowls, Mark [1 ]
Deng, Yue [2 ]
Kulick, Doina [3 ]
Destaillats, Hugo [4 ]
Forzani, Erica S. [1 ,2 ]
机构
[1] Arizona State Univ, Sch Engn Matter Transport & Energy, Tempe, AZ 85287 USA
[2] Arizona State Univ, Ctr Bioelect & Biosensors, Biodesign Inst, Tempe, AZ 85287 USA
[3] Mayo Clin, Scottsdale, AZ USA
[4] Lawrence Berkeley Natl Lab, Indoor Environm Grp, Berkeley, CA USA
关键词
passive sensors; metabolic rate; indoor air quality; non-invasive sensors; environmental sensors; BUILDING SYNDROME SYMPTOMS; CARBON-DIOXIDE; ENERGY-EXPENDITURE; CO2; CONCENTRATIONS; PHYSICAL-ACTIVITY; VENTILATION; ASSOCIATIONS; EXPOSURE;
D O I
10.1088/1752-7163/aaaec9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present work introduces the use of environmental sensors to assess indoor air quality (IAQ) in combination with human biometrics. The sensor array included temperature, relative humidity, carbon dioxide, and noise monitors. The array was used in a classroom as well as in a vehicle cabin to assess the carbon dioxide production rate of individuals in a closed ventilation environment. Analysis of carbon dioxide production allowed for the quantification of the average metabolic rate of the group of individuals in the classroom, and for one individual in the vehicle cabin. These results yielded a mere5% difference from the values assessed using commercial metabolic rate instruments, and averaged values from epidemiological studies. The results presented in this work verify the feasibility of determining an individual's metabolic rate using passive environmental sensors; these same sensors are able to provide a metric of IAQ that helps characterize the safety of the environment in which the individual is present.
引用
收藏
页数:13
相关论文
共 33 条
  • [1] Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments
    Allen, Joseph G.
    MacNaughton, Piers
    Satish, Usha
    Santanam, Suresh
    Vallarino, Jose
    Spengler, John D.
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) : 805 - 812
  • [2] [Anonymous], 2016, EXERCISE PHYSL NUTR
  • [3] Associations between indoor CO2 concentrations and sick building syndrome symptoms in US office buildings:: An analysis of the 1994-1996 BASE study data
    Apte, MG
    Fisk, WJ
    Daisey, JM
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04): : 246 - 257
  • [4] Atkinson J, 2009, NATURAL VENTILATION FOR INFECTION CONTROL IN HEALTH-CARE SETTINGS, P1
  • [5] Bouhamra WS, 1998, ASHRAE J, V40, P42
  • [6] Bridgeman D, 2015, GLOB J OBES DIABETES, V2, P004, DOI DOI 10.17352/2455-8583
  • [7] Deng Y, 2017, COMP RESTING METABOL
  • [8] Daily energy expenditure in Mexican and USA Pima Indians: low physical activity as a possible cause of obesity
    Esparza, J
    Fox, C
    Harper, IT
    Bennett, PH
    Schulz, LO
    Valencia, ME
    Ravussin, E
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 2000, 24 (01) : 55 - 59
  • [9] Concentrations of carbon dioxide in the cabin of a small passenger car
    Gladyszewska-Fiedoruk, Katarzyna
    [J]. TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2011, 16 (04) : 327 - 331
  • [10] Godish T., 1995, SICK BUILDINGS DEFIN