A novel naphazoline-selective membrane sensor and its pharmaceutical applications

被引:41
作者
Ghoreishi, SM [1 ]
Behpour, M [1 ]
Nabi, M [1 ]
机构
[1] Kashan Univ, Fac Sci, Dept Chem, Kashan 873175167, Iran
关键词
ion-selective electrode; naphazoline hydrochloride; coated wire;
D O I
10.1016/j.snb.2005.04.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New naphazoline (NPZ) ion selective membrane electrodes of both conventional and coated graphite types were prepared based on the ion-pair of naphazoline tetraphenylborate (NPZ-TPB). The conventional type electrode was fully characterized in terms of membrane composition, life span, pH, ionic strength and temperature. The electrode exhibited a Nernstian response for naphazoline in the concentration range 1.0 x 10(-5) to 5.0 x 10(-2) and 5.0 x 10(-6) to 5.0 x 10(-2) M with a slope of 58.4 +/- 1.1 and 57.0 +/- 0.1 mV/concentration decade and a limit of detection of 4.0 x 10(-6) and 2.5 x 10(-6) M for conventional and coated graphite types, respectively. It could be used in the pH range 3.0-8.0. It was applied to potentiometric determination of naphazoline in pure state and pharmaceutical preparation under batch conditions. The selectivity of the electrode toward a large number of inorganic cations, sugars and amino acids was tested. The solubility product of the ion-pair and the formation constant of the precipitation reaction leading to the ion-pair formation were determined conductometrically. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:963 / 969
页数:7
相关论文
共 20 条
[1]  
ABDELGHANI NT, 2003, IL FARMACO, V58, P581
[2]  
Antropov L.I., 1977, THEORETICAL ELECTROC
[3]  
BAUER HH, 1978, INSTRUMENTAL ANAL, P117
[4]  
BUCK RP, 1994, PURE APPL CHEM, V66, P527
[5]   Room-temperature phosphorimetric method for the determination of the drug naphazoline in pharmaceutical preparations [J].
Carretero, AS ;
Blanco, CC ;
Díaz, BC ;
Gutiérrez, AF .
ANALYST, 1998, 123 (05) :1069-1071
[6]  
Cosofret V.V., 1992, PHARM APPL MEMBRANE
[7]   Determination of prednisolone, naphazoline, and phenylephrine in local pharmaceutical preparations by micellar electrokinetic chromatography [J].
Gallego, JML ;
Arroyo, JP .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :947-952
[8]   Sustained prediction ability of net analyte preprocessing methods using reduced calibration sets. Theoretical and experimental study involving the spectrophotometric analysis of multicomponent mixtures [J].
Goicoechea, HC ;
Olivieri, AC .
ANALYST, 2001, 126 (07) :1105-1112
[9]   Conductimetric determination of reproterol HCl and pipazethate HCl and salbutamol sulphate in their pharmaceutical formulations [J].
Issa, YM ;
Shoukry, AF ;
El-Nashar, RM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (03) :379-386
[10]  
LIANG Y, 1985, YAOWU FENXI ZAZHI, V5, P81