Automated 3D Segmentation of Intraretinal Surfaces in SD-OCT Volumes in Normal and Diabetic Mice

被引:13
作者
Antony, Bhavna J. [1 ,2 ]
Jeong, Woojin [3 ,4 ,5 ]
Abramoff, Michael D. [1 ,2 ,5 ,6 ]
Vance, Joseph [7 ]
Sohn, Elliott H. [5 ]
Garvin, Mona K. [1 ,2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[2] VA Ctr Prevent & Treatment Visual Loss, Iowa City, IA USA
[3] Dong A Univ, Dept Ophthalmol, Coll Med, Busan, South Korea
[4] Med Res Ctr, Busan, South Korea
[5] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
[6] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[7] Bioptigen Inc, Morrisville, NC USA
关键词
SD-OCT; mice; automated segmentation; diabetes; OPTICAL COHERENCE TOMOGRAPHY; RETINAL LAYERS; THICKNESS MEASUREMENTS; IMAGES;
D O I
10.1167/tvst.3.5.8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe an adaptation of an existing graph-theoretic method (initially developed for human optical coherence tomography [OCT] images) for the three-dimensional (3D) automated segmentation of 10 intraretinal surfaces in mice scans, and assess the accuracy of the method and the reproducibility of thickness measurements. Methods: Ten intraretinal surfaces were segmented in repeat spectral domain (SD)-OCT volumetric images acquired from normal (n = 8) and diabetic (n = 10) mice. The accuracy of the method was assessed by computing the border position errors of the automated segmentation with respect to manual tracings obtained from two experts. The reproducibility was statistically assessed for four retinal layers within eight predefined regions using the mean and SD of the differences in retinal thickness measured in the repeat scans, the coefficient of variation (CV) and the intraclass correlation coefficients (ICC; with 95% confidence intervals [CIs]). Results: The overall mean unsigned border position error for the 10 surfaces computed over 97 B-scans (10 scans, 10 normal mice) was 3.16 +/- 0.91 mu m. The overall mean differences in retinal thicknesses computed from the normal and diabetic mice were 1.86 +/- 0.95 and 2.15 +/- 0.86 lm, respectively. The CV of the retinal thicknesses for all the measured layers ranged from 1.04% to 5%. The ICCs for the total retinal thickness in the normal and diabetic mice were 0.78 [0.10, 0.92] and 0.83 [0.31, 0.96], respectively. Conclusion: The presented method (publicly available as part of the Iowa Reference Algorithms) has acceptable accuracy and reproducibility and is expected to be useful in the quantitative study of intraretinal layers in mice. Translational Relevance: The presented method, initially developed for human OCT, has been adapted for mice, with the potential to be adapted for other animals as well. Quantitative in vivo assessment of the retina in mice allows changes to be measured longitudinally, decreasing the need for them.
引用
收藏
页数:11
相关论文
共 36 条
[1]  
Abramoff Michael D, 2010, IEEE Rev Biomed Eng, V3, P169, DOI 10.1109/RBME.2010.2084567
[2]  
[Anonymous], 2012, R LANG ENV STAT COMP
[3]   A combined machine-learning and graph-based framework for the segmentation of retinal surfaces in SD-OCT volumes [J].
Antony, Bhavna J. ;
Abramoff, Michael D. ;
Harper, Matthew M. ;
Jeong, Woojin ;
Sohn, Elliott H. ;
Kwon, Young H. ;
Kardon, Randy ;
Garvin, Mona K. .
BIOMEDICAL OPTICS EXPRESS, 2013, 4 (12) :2712-2728
[4]  
Antony BJ, 2010, P SPIE MED IMAGING 2, V7626
[5]  
Antony BJ, 2012, P SPIE 2012 MED IMAG, V8314
[6]   Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation [J].
Bagci, Ahmet Murat ;
Shahidi, Mahnaz ;
Ansari, Rashid ;
Blair, Michael ;
Blair, Norman Paul ;
Zelkha, Ruth .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (05) :679-687
[7]   Spectral-Domain Optical Coherence Tomography as a Noninvasive Method to Assess Damaged and Regenerating Adult Zebrafish Retinas [J].
Bailey, Travis J. ;
Davis, Darin H. ;
Vance, Joseph E. ;
Hyde, David R. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) :3126-3138
[8]   Towards quantitative analysis of retinal features in optical coherence tomography [J].
Baroni, Maurizio ;
Fortunato, Pina ;
La Torre, Agostino .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (04) :432-441
[9]   Quantification of photoreceptor layer thickness in normal eyes using optical coherence tomography [J].
Chan, Annie ;
Duker, Jay S. ;
Ishikawa, Hiroshi ;
Ko, Tony H. ;
Schuman, Joel S. ;
Fujimoto, James G. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (06) :655-660
[10]   Automated segmentation of the macula by optical coherence tomography [J].
Fabritius, Tapio ;
Makita, Shuichi ;
Miura, Masahiro ;
Myllyla, Risto ;
Yasuno, Yoshiaki .
OPTICS EXPRESS, 2009, 17 (18) :15659-15669