A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental Validation

被引:26
作者
Colacino, Francesco Maria [1 ]
Moscato, Francesco [1 ]
Piedimonte, Fabio [2 ]
Danieli, Guido [1 ]
Nicosia, Salvatore [2 ]
Arabia, Maurizio [1 ]
机构
[1] Univ Calabria, Dept Mech Engn, I-87036 Arcavacata Di Rende, Italy
[2] Univ Roma Tor Vergata, Dipartimento Informat Sistemi & Prod, Rome, Italy
关键词
D O I
10.1097/MAT.0b013e31818a5c93
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article describes an elastance-based mock ventricle able to reproduce the correct ventricular pressure-volume relationship and its correct interaction with the hydraulic circuit connected to it. A real-time control of the mock ventricle was obtained by a new left ventricular mathematical model including resistive and inductive terms added to the classical Suga-Sagawa elastance model throughout the whole cardiac cycle. A valved piston pump was used to mimic the left ventricle. The pressure measured into the pump chamber was fed back into the mathematical model and the calculated reference left ventricular volume was used to drive the piston. Results show that the classical model is very sensitive to pressure disturbances, especially during the filling phase, while the modified model is able to filter out the oscillations thus eliminating their detrimental effects. The presented model is thus suitable to control mock ventricles in real-time, where sudden pressure disturbances represent a key issue and are not negligible. This real-time controlled mock ventricle is able to reproduce the elastance mechanism of a natural ventricle by mimicking its preload (mean atrial pressure) and afterload (mean aortic pressure) sensitivity, i.e., the Starling law. Therefore, it can be used for designing and testing cardiovascular prostheses due to its capability to reproduce the correct ventricle-vascular system interaction. ASAIO Journal 2008; 54:563-573.
引用
收藏
页码:563 / 573
页数:11
相关论文
共 48 条
[1]  
[Anonymous], 2000, MED PHYSL
[2]   A NEW TEST CIRCULATORY-SYSTEM FOR RESEARCH IN CARDIOVASCULAR ENGINEERING [J].
ARABIA, M ;
AKUTSU, T .
ANNALS OF BIOMEDICAL ENGINEERING, 1984, 12 (01) :29-48
[3]   Elastance-based control of a mock circulatory system [J].
Baloa, LA ;
Boston, JR ;
Antaki, JF .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (03) :244-251
[4]   Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers [J].
Burkhoff, D ;
Mirsky, I ;
Suga, H .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 289 (02) :H501-H512
[5]   INTERNAL CAPACITANCE AND RESISTANCE ALLOW PREDICTION OF RIGHT VENTRICLE OUTFLOW [J].
CAMPBELL, KB ;
RINGO, JA ;
WAKAO, Y ;
KLAVANO, PA ;
ALEXANDER, JE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (01) :H99-H112
[6]   Modeling, analysis, and validation of a pneumatically driven left ventricle for use in mock circulatory systems [J].
Colacino, F. M. ;
Arabia, M. ;
Moscato, F. ;
Danieli, G. A. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (08) :829-839
[7]  
Colacino FM, 2005, INT J ARTIF ORGANS, V28, P817
[8]   Left ventricle load impedance control by apical VAD can help heart recovery and patient perfusion: A numerical study [J].
Colacino, Francesco M. ;
Moscato, Francesco ;
Piedimonte, Fabio ;
Arabia, Maurizio ;
Danieli, Guido A. .
ASAIO JOURNAL, 2007, 53 (03) :263-277
[9]   CONTRIBUTION OF EXTERNAL FORCES TO LEFT-VENTRICULAR DIASTOLIC PRESSURE - IMPLICATIONS FOR THE CLINICAL USE OF THE STARLING LAW [J].
DAUTERMAN, K ;
PAK, PH ;
MAUGHAN, WL ;
NUSSBACHER, A ;
ARIE, S ;
LIU, CP ;
KASS, DA .
ANNALS OF INTERNAL MEDICINE, 1995, 122 (10) :737-742
[10]   DESIGN OF A HYDRAULIC ANALOG OF CIRCULATORY-SYSTEM FOR EVALUATING ARTIFICIAL HEARTS [J].
DONOVAN, FM .
BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1975, 3 (04) :439-449