Total hip replacement arthroplasty with Mallory-Head system-minimum ten-year follow-up results

被引:9
作者
Song, Joo-Hyoun [2 ]
Kim, Dong-Hyun [2 ]
Kim, Juyoung [1 ]
机构
[1] Catholic Univ Korea, Dept Orthoped Surg, Inchon St Marys Hosp, Inchon 403720, South Korea
[2] Catholic Univ Korea, Dept Orthoped Surg, St Vincents Hosp, Suwon, South Korea
关键词
FEMORAL COMPONENT; OSTEOLYSIS; CEMENT; WEAR; OSTEOARTHRITIS; PROSTHESIS; FIXATION; INGROWTH; FAILURE; BONE;
D O I
10.1007/s00264-012-1627-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to assess the clinical and radiographic results of a total hip arthroplasty with the double tapered Mallory-Head system. The clinical and radiographic results of a consecutive series of 81 total hip replacements in 75 patients were reviewed 10-15 years (average 11.4 years) postoperatively. The patients' underlying conditions were avascular necrosis in 46 hips (57 %), osteoarthritis in 12 hips (15 %), RA in nine hips (11 %), and others. Clinical results were evaluated based on the modified Harris hip score and modified Merle d'Aubign,-Postel score. A radiographic analysis was performed. The average modified Harris hip score improved from a preoperative score of 56 points to a postoperative 92 points. The average modified Merle d'Aubign,-Postel score was 15 points at the latest follow up, and 55 hips (68 %) were classified as the clinical grades of excellent or good results. One acetabular component was revised because of loosening, and one was revised for recurrent dislocation. The clinical and radiological evaluations of the total hip replacements using the Mallory-Head system showed good results.
引用
收藏
页码:2055 / 2059
页数:5
相关论文
共 50 条
[21]   Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles [J].
Yan, Yufei ;
Chen, Hao ;
Feng, Jianmin ;
Chen, Kaizhe ;
Zhou, Kaidi ;
Hong, Weixiang ;
Wang, Yi ;
Liu, Zhihong ;
Zhang, Jiong ;
Yang, Qingming ;
Guo, Lei ;
He, Chuan .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) :723-730
[22]   Outcomes of Exeter cemented total hip arthroplasty in a county hospital: survivorship of eight hundred and ninety four hips with a minimum ten-year follow up [J].
Kristof, Janvari ;
Gupta, Devanshu ;
Szabo, Laszlo ;
Bucsi, Laszlo ;
Zahar, Akos .
INTERNATIONAL ORTHOPAEDICS, 2024, 48 (03) :729-735
[23]   The Outcome of Posterior-Stabilized, Rotating Platform Total Knee Arthroplasty at a Minimum Ten-Year Follow-up, a Middle East Institution Experience [J].
Khalifa, Ahmed A. ;
Fayez, Mostafa ;
Elkady, Hesham ;
Abdelaal, Ahmed M. ;
Elassal, Maher A. .
JOURNAL OF KNEE SURGERY, 2022, 35 (07) :718-724
[24]   Kudo type-5 total elbow arthroplasty for patients with rheumatoid arthritis A MINIMUM TEN-YEAR FOLLOW-UP STUDY [J].
Kodama, A. ;
Mizuseki, T. ;
Adachi, N. .
BONE & JOINT JOURNAL, 2017, 99B (06) :818-823
[25]   Second-generation uncemented total hip arthroplasty: a minimum 20-year follow-up [J].
McLaughlin, J. R. ;
Lee, K. R. ;
Johnson, M. A. .
BONE & JOINT OPEN, 2021, 2 (01) :33-39
[26]   Cementless Anatomic Total Hip Femoral Component With Circumferential Porous Coating for Hips With Developmental Dysplasia: A Minimum Ten-Year Follow-Up Period [J].
Kaneuji, Ayumi ;
Sugimori, Tanzo ;
Ichiseki, Toru ;
Fukui, Kiyokazu ;
Takahashi, Eiji ;
Matsumoto, Tadami .
JOURNAL OF ARTHROPLASTY, 2013, 28 (10) :1746-1750
[27]   The importance of adequate stem anteversion for rotational stability in cemented total hip replacement A RADIOSTEREOMETRIC STUDY WITH TEN-YEAR FOLLOW-UP [J].
Kiernan, S. ;
Hermann, K. L. ;
Wagner, P. ;
Ryd, L. ;
Flivik, G. .
BONE & JOINT JOURNAL, 2013, 95B (01) :23-30
[28]   Long-term results of uncemented stems in total hip arthroplasty. Analysis of survival rates with a minimum 15-year follow-up [J].
Merle, C. ;
Clarius, M. ;
Aldinger, P. R. .
ORTHOPADE, 2010, 39 (01) :80-86
[29]   Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients A PROSPECTIVE RANDOMISED CONTROLLED TRIAL [J].
Atrey, A. ;
Ward, S. E. ;
Khoshbin, A. ;
Hussain, N. ;
Bogoch, E. ;
Schemitsch, E. H. ;
Waddell, J. P. .
BONE & JOINT JOURNAL, 2017, 99B (12) :1590-1595
[30]   The Cementless Anatomic Benoist Girard (ABG) II Total Hip Arthroplasty A Minimum 8-Year Follow-Up Study [J].
Nourissat, Christian ;
Essig, Jerome ;
Asencio, Gerard .
JOURNAL OF ARTHROPLASTY, 2013, 28 (04) :707-711