Radiochemical Feasibility of Mixing of 99mTc-MAA and 90Y-Microspheres with Omnipaque Contrast

被引:0
作者
Yang, Chang-Tong [1 ,2 ]
Ngam, Pei Ing [1 ,3 ]
Phua, Vanessa Jing Xin [1 ]
Yu, Sidney Wing Kwong [1 ]
Apoorva, Gogna [2 ,4 ]
Ng, David Chee Eng [1 ,2 ]
Huang, Hian Liang [1 ,2 ]
机构
[1] Singapore Gen Hosp, Dept Nucl Med & Mol Imaging, Radiol Sci Div, Outram Rd, Singapore 169608, Singapore
[2] Duke NUS Med Sch, 8 Coll Rd, Singapore 169857, Singapore
[3] Natl Univ Singapore Hosp, Dept Diagnost Imaging, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore
[4] Singapore Gen Hosp, Dept Vasc & Intervent Radiol, Radiol Sci Div, Outram Rd, Singapore 169608, Singapore
来源
MOLECULES | 2022年 / 27卷 / 21期
关键词
radiochemical purity; Y-90; microspheres; Technetium-99m macroaggregated albumin(Tc-99m-MAA); Y-90-SIRT radioembolization; omnipaque contrast; INTERNAL RADIATION-THERAPY; CANCER LIVER METASTASES; COLORECTAL-CANCER; HEPATOCELLULAR-CARCINOMA; Y-90; RADIOEMBOLIZATION; SPECT/CT; ALBUMIN; SIRT;
D O I
10.3390/molecules27217646
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Yttrium-90 (Y-90) microspheres are widely used for the treatment of liver-dominant malignant tumors. They are infused via catheter into the hepatic artery branches supplying the tumor under fluoroscopic guidance based on pre-therapy angiography and Technetium-99m macroaggregated albumin (Tc-99m-MAA) planning. However, at present, these microspheres are suspended in radiolucent media such as dextrose 5% (D5) solution. In order to monitor the real-time implantation of the microspheres into the tumor, the Y-90 microspheres could be suspended in omnipaque contrast for allowing visualization of the correct distribution of the microspheres into the tumor. The radiochemical purity of mixing Y-90-microspheres in various concentrations of omnipaque was investigated. The radiochemical purity and feasibility of mixing Tc-99m-MAA with various concentrations of a standard contrast agent were also investigated. Results showed the radiochemical feasibility of mixing Y-90-microspheres with omnipaque is radiochemically acceptable for allowing real-time visualization of radioembolization under fluoroscopy.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Predictive value of 99mTc-MAA-based dosimetry in personalized 90Y-SIRT planning for liver malignancies
    Riveira-Martin, Mercedes
    Akhavanallaf, Azadeh
    Mansouri, Zahra
    Bianchetto Wolf, Nicola
    Salimi, Yazdan
    Ricoeur, Alexis
    Mainta, Ismini
    Garibotto, Valentina
    Lopez Medina, Antonio
    Zaidi, Habib
    EJNMMI RESEARCH, 2023, 13 (01)
  • [22] Analysis of differences between 99mTc-MAA SPECT- and 90Y-microsphere PET-based dosimetry for hepatocellular carcinoma selective internal radiation therapy
    Kafrouni, Marilyne
    Allimant, Carole
    Fourcade, Marjolaine
    Vauclin, Sebastien
    Guiu, Boris
    Mariano-Goulart, Denis
    Ben Bouallegue, Faycal
    EJNMMI RESEARCH, 2019, 9 (1)
  • [23] The Significance of 99mTc-MAA SPECT/CT Liver Perfusion Imaging in Treatment Planning for 90Y-Microsphere Selective Internal Radiation Treatment
    Ahmadzadehfar, Hojjat
    Sabet, Amir
    Biermann, Kim
    Muckle, Marianne
    Brockmann, Holger
    Kuhl, Christiane
    Wilhelm, Kai
    Biersack, Hans-Juergen
    Ezziddin, Samer
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1206 - 1212
  • [24] A Workflow for Dosimetry of 90Y Radioembolization Based on Quantitative 99mTc-MAA SPECT/CT Imaging and a 3D-Printed Phantom
    Ungania, Sara
    D'Arienzo, Marco
    Mezzenga, Emilio
    Pizzi, Giuseppe
    Vallati, Giulio
    Ianiro, Anna
    Rea, Sandra
    Sciuto, Rosa
    Soriani, Antonella
    Strigari, Lidia
    APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [25] Optimization of 99mTc-MAA SPECT/CT Imaging for 90Y Radioembolization Using a 3D-Printed Phantom
    Ungania, Sara
    D'Arienzo, Marco
    Nocentini, Sandro
    D'Andrea, Marco
    Bruzzaniti, Vicente
    Marconi, Raffaella
    Mezzenga, Emilio
    Cassano, Bartolomeo
    Infusino, Erminia
    Guerrisi, Antonino
    Soriani, Antonella
    Strigari, Lidia
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [26] Accurate non-tumoral 99mTc-MAA absorbed dose prediction to plan optimized activities in liver radioembolization using resin microspheres
    d'Abadie, Philippe
    Walrand, Stephan
    Hesse, Michel
    Amini, Nadia
    Lhommel, Renaud
    Sawadogo, Kiswendsida
    Jamar, Francois
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 250 - 257
  • [27] EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres
    Chiesa, Carlo
    Sjogreen-Gleisner, Katarina
    Walrand, Stephan
    Strigari, Lidia
    Flux, Glenn
    Gear, Jonathan
    Stokke, Caroline
    Gabina, Pablo Minguez
    Bernhardt, Peter
    Konijnenberg, Mark
    EJNMMI PHYSICS, 2021, 8 (01)
  • [28] 99mTc-MAA overestimates the absorbed dose to the lungs in radioembolization: a quantitative evaluation in patients treated with 166Ho-microspheres
    Elschot, Mattijs
    Nijsen, Johannes F. W.
    Lam, Marnix G. E. H.
    Smits, Maarten L. J.
    Prince, Jip F.
    Viergever, Max A.
    van den Bosch, Maurice A. A. J.
    Zonnenberg, Bernard A.
    de Jong, Hugo W. A. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (10) : 1965 - 1975
  • [29] Comparative dosimetry between 99mTc-MAA SPECT/CT and 90Y PET/CT in primary and metastatic liver tumors
    Alexandre Jadoul
    Claire Bernard
    Pierre Lovinfosse
    Laurent Gérard
    Henri Lilet
    Olivier Cornet
    Roland Hustinx
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 828 - 837
  • [30] Patient-specific gamma-index analysis to evaluate 99mTc-MAA as a predictor for 90Y glass microspheres liver radioembolisation dosimetry
    Ferreira, Paulo
    Oliveira, Francisco P. M.
    Parafita, Rui
    Girao, Pedro S.
    Correia, Paulo L.
    Costa, Durval C.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2019, 7 (5-6) : 583 - 589