On the thermal cooling of central processing unit of the PCs with vapor chamber

被引:38
作者
Naphon, Paisarn [1 ]
Wongwises, Somchai [2 ]
Wiriyasart, Songkran [1 ]
机构
[1] Srinakharinwirot Univ, Dept Mech Engn, Fac Engn, Thermofluids & Heat Transfer Enhancement Lab TFHT, Ongkharak 26120, Nakhorn Nayok, Thailand
[2] King Mongkuts Univ Technol Thonburi, Dept Mech Engn, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Bangkok 10140, Thailand
关键词
Vapor chamber; Electronics cooling; Central processing unit; HEAT-PIPE; PERFORMANCE; SYSTEM; SINK;
D O I
10.1016/j.icheatmasstransfer.2012.07.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation on the thermal cooling of vapor chamber for cooling computer processing unit of the personal computer is performed. Two different configurations of the vapor chambers with de-ionized water as working fluid are tested under the real operating conditions of PCs. Parametric studies including different aspect ratios, fill ratios, and operating conditions of PC on the CPU temperature are considered. It was found that the vapor chamber cooling technique has significant effect on the thermal cooling of CPU. Average CPU temperatures obtained from the vapor chamber cooling system are 4.1%, 6.89% lower than those from the conventional cooling system for no load and 90% operating loads, respectively. In additional, this cooling system requires 6.89%, 10.53% lower energy consumption for no load and 90% operating loads, respectively. The results of this study are of technological importance for the efficient design of cooling systems of the personal computers or electronic devices to enhance cooling performance. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1165 / 1168
页数:4
相关论文
共 29 条
  • [11] Multiple quasi-steady states in a closed loop pulsating heat pipe
    Khandekar, Sameer
    Gautam, Anant Prasad
    Sharma, Pavan K.
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (03) : 535 - 546
  • [12] Effects of shield on thermal-fluid performance of vapor chamber heat sink
    Li, Hung-Yi
    Chiang, Ming-Hung
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (7-8) : 1410 - 1419
  • [13] Thermal performance of plate-fin vapor chamber heat sinks
    Li, Hung-Yi
    Chiang, Ming-Hung
    Lee, Chih-I
    Yang, Wen-Jei
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) : 731 - 738
  • [14] Experimental investigation on startup of a novel two-phase cooling loop
    Liu Jie
    Pei Nian-qiang
    Guo Kai-hua
    He Zhen-hui
    Li Ting-xuen
    Gu Jian-ming
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (04) : 939 - 946
  • [15] Development of an OAPCP-micropump liquid cooling system in a laptop
    Ma, Hsiao-Kang
    Chen, Bo-Ren
    Gao, Jhong Jhih
    Lin, Cheng-Yao
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (03) : 225 - 232
  • [16] Naphon P., 2012, J ELECT COOLING THER, V1, P1
  • [17] Heat transfer to sub-cooled binary solution in horizontal tube
    Orian, G.
    Jelinek, M.
    Levy, A.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (04) : 661 - 669
  • [18] Experimental and theoretical study of a vapour chamber based heat spreader for avionics applications
    Reyes, M.
    Alonso, D.
    Arias, J. R.
    Velazquez, A.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 37 : 51 - 59
  • [19] Two-phase closed thermosyphon vapor-chamber system for electronic cooling
    Tsai, Te-En
    Wu, Hsin-Hsuan
    Chang, Chih-Chung
    Chen, Sih-Li
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (05) : 484 - 489
  • [20] Loop heat pipe for cooling of high-power electronic components
    Vasiliev, Leonid
    Lossouarn, David
    Romestant, Cyril
    Alexandre, Alain
    Bertin, Yves
    Piatsiushyk, Yauheni
    Romanenkov, Vladimir
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (1-2) : 301 - 308