Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization

被引:9
作者
Asano, Yudai [1 ]
Tada, Akihiro [1 ]
Shinya, Takayoshi [1 ]
Masaoka, Yoshihisa [1 ]
Iguchi, Toshihiro [1 ]
Sato, Shuhei [2 ]
Kanazawa, Susumu [1 ]
机构
[1] Okayama Univ Hosp, Dept Radiol, Kita Ku, 2-5-1 Shikatacho, Okayama, Okayama 7008558, Japan
[2] Kawasaki Univ Med Welf, Dept Hlth Informat, Okayama, Japan
关键词
Artifact reduction; Metal implants; CT; Pulmonary arteriovenous malformation; Single-energy metal artifact reduction algorithm; IMPROVED IMAGE QUALITY; CT EVALUATION; ALGORITHM; REPERFUSION; IMPLANTS; HIP; EMBOLOTHERAPY; PROSTHESES;
D O I
10.1007/s11604-018-0723-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 +/- 11.0 years; number of embolization coils, 9.8 +/- 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6-211.9] Hounsfield units [HU] vs. 243.9 [220.4-286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 26 条
[21]  
Tatsugami F, 2016, BRIT J RADIOL, V89, P1067
[22]   Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures [J].
Teixeira, Pedro Augusto Gondim ;
Meyer, Jean-Baptiste ;
Baumann, Cedric ;
Raymond, Ariane ;
Sirveaux, Francois ;
Coudane, Henry ;
Blum, Alain .
SKELETAL RADIOLOGY, 2014, 43 (09) :1237-1246
[23]   PAVM Embolization: An Update [J].
Trerotola, Scott O. ;
Pyeritz, Reed E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :837-845
[24]   Metal artefact reduction for patients with metallic dental fillings in helical neck computed tomography: comparison of adaptive iterative dose reduction 3D (AIDR 3D), forward-projected model-based iterative reconstruction solution (FIRST) and AIDR 3D with single-energy metal artefact reduction (SEMAR) [J].
Yasaka, Koichiro ;
Kamiya, Kouhei ;
Irie, Ryusuke ;
Maeda, Eriko ;
Sato, Jiro ;
Ohtomo, Kuni .
DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (07)
[25]   Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses [J].
Yasaka, Koichiro ;
Maeda, Eriko ;
Hanaoka, Shouhei ;
Katsura, Masaki ;
Sato, Jiro ;
Ohtomo, Kuni .
JAPANESE JOURNAL OF RADIOLOGY, 2016, 34 (09) :625-632
[26]   Dual-Energy CT-Based Monochromatic Imaging [J].
Yu, Lifeng ;
Leng, Shuai ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S9-S15