Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization

被引:9
作者
Asano, Yudai [1 ]
Tada, Akihiro [1 ]
Shinya, Takayoshi [1 ]
Masaoka, Yoshihisa [1 ]
Iguchi, Toshihiro [1 ]
Sato, Shuhei [2 ]
Kanazawa, Susumu [1 ]
机构
[1] Okayama Univ Hosp, Dept Radiol, Kita Ku, 2-5-1 Shikatacho, Okayama, Okayama 7008558, Japan
[2] Kawasaki Univ Med Welf, Dept Hlth Informat, Okayama, Japan
关键词
Artifact reduction; Metal implants; CT; Pulmonary arteriovenous malformation; Single-energy metal artifact reduction algorithm; IMPROVED IMAGE QUALITY; CT EVALUATION; ALGORITHM; REPERFUSION; IMPLANTS; HIP; EMBOLOTHERAPY; PROSTHESES;
D O I
10.1007/s11604-018-0723-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 +/- 11.0 years; number of embolization coils, 9.8 +/- 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6-211.9] Hounsfield units [HU] vs. 243.9 [220.4-286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.
引用
收藏
页码:285 / 294
页数:10
相关论文
共 26 条
[1]   Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering [J].
Bal, Matthieu ;
Spies, Lothar .
MEDICAL PHYSICS, 2006, 33 (08) :2852-2859
[2]   Pulmonary arteriovenous malformation (PAVM) reperfusion after percutaneous embolization: Sensitivity and specificity of non-enhanced CT [J].
Belanger, Chantale ;
Chartrand-Lefebvre, Carl ;
Soulez, Gilles ;
Faughnan, Marie E. ;
Tahir, Muhammad Ramzan ;
Giroux, Marie-France ;
Gilbert, Patrick ;
Perreault, Pierre ;
Bouchard, Louis ;
Oliva, Vincent L. ;
Therasse, Eric .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) :150-157
[3]   Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model [J].
Fang, Jieming ;
Zhang, Da ;
Wilcox, Carol ;
Heidinger, Benedikt ;
Raptopoulos, Vassilios ;
Brook, Alexander ;
Brook, Olga R. .
ABDOMINAL RADIOLOGY, 2017, 42 (03) :742-748
[4]   A newly-developed metal artifact reduction algorithm improves the visibility of oral cavity lesions on 320-MDCT volume scans [J].
Funama, Yoshinori ;
Taguchi, Katsuyuki ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Hirata, Kenichiro ;
Yuki, Hideaki ;
Kidoh, Masafumi ;
Hatemura, Masahiro ;
Yamashita, Yasuyuki .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01) :66-71
[5]   Vein Diameter on Unenhanced Multidetector CT Predicts Reperfusion of Pulmonary Arteriovenous Malformation after Embolotherapy [J].
Gamondes, Delphine ;
Si-Mohamed, Salim ;
Cottin, Vincent ;
Gonidec, Sophie ;
Boussel, Loic ;
Douek, Philippe ;
Revel, Didier .
EUROPEAN RADIOLOGY, 2016, 26 (08) :2723-2729
[6]   Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers [J].
Hirata, Kenichiro ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Kidoh, Masafumi ;
Funama, Yoshinori ;
Yuki, Hideaki ;
Yoshida, Morikatsu ;
Yamashita, Yasuyuki .
JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (10) :650-656
[7]  
Kidoh M, 2017, ACTA RADIOL OPEN, V6, DOI 10.1177/2058460117693463
[8]   Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm [J].
Kidoh, Masafumi ;
Utsunomiya, Daisuke ;
Ikeda, Osamu ;
Tamura, Yoshitaka ;
Oda, Seitaro ;
Funama, Yoshinori ;
Yuki, Hideaki ;
Nakaura, Takeshi ;
Kawano, Takayuki ;
Hirai, Toshinori ;
Yamashita, Yasuyuki .
EUROPEAN RADIOLOGY, 2016, 26 (05) :1378-1386
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]   Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software [J].
Lee, Young Han ;
Park, Kwan Kyu ;
Song, Ho-Taek ;
Kim, Sungjun ;
Suh, Jin-Suck .
EUROPEAN RADIOLOGY, 2012, 22 (06) :1331-1340