Treatment of heavy metal polluted industrial wastewater by a new water treatment process: ballasted electroflocculation

被引:39
作者
Brahmi, Khaled [1 ]
Bouguerra, Wided [1 ]
Harbi, Soumaya [1 ]
Elaloui, Elimame [2 ]
Loungou, Mouna [3 ]
Hamrouni, Bechir [1 ]
机构
[1] Univ Tunis El Manar, UR Traitement & Dessalement Eaux, Dept Chim, Fac Sci Tunis, Manar Ii 2092, Tunisia
[2] Campus Univ Sidi Ahmed Zarroug, UR Mat Environm & Energie, Dept Chim, Fac Sci Gafsa, Gafsa 2112, Tunisia
[3] Grp Chim Tunisien, Usine MDhilla Gafsa, Km 14 Route MDhilla, Gafsa 2100, Tunisia
关键词
New wastewater treatment process; Electrochemistry; Ballasted electroflocculation; Micro sand; Mining wastewater treatment; High heavy metals removal; Low operating cost; RESPONSE-SURFACE METHODOLOGY; ELECTROCOAGULATION; FLOCCULATION; REMOVAL;
D O I
10.1016/j.jhazmat.2017.11.051
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This laboratory study investigated the parameters efficiency of the new technology: ballasted electro-flocculation (BEF) using aluminum (Al) electrodes to remove cadmium and zinc from industrial mining wastewater (MWW). The principle of the BEF process is based on the use of micro-sand and polymer together to increase the weight of the flocs and the rate at which they settle is radically changing the electrocoagulation-electroflocculation settling methodology. Based on the examination of the operation parameters one by one, the best removal percentage was obtained at a current intensity of 2 A, a the flow rate of 20 L/h, a micro-sand dose of 6 g/L, a polyethyleneimine (PEI) polymer dose of 100 mg, the contact times of 30 min, a stirring speed of 50 RPM, a monopolar configuration of the electrodes, and an electrodes number of 10. The results showed that the flow rate and the current density have a preponderant effect on the variability of the quality of the settled water. In comparison, filterability was found to be More sensitive to number of electrodes, micro sand dosages and current density. It was dependent on the ratio of microsand to PEI polymer dosage, and improved when this ratio increased. Response surface methodology was applied to evaluate the main effects and interactions among stirring speed, polymer dose, current intensity, and electrodes number. The removal of Cd and Zn from industrial MWW was done for very low cost of 0.1 TND/m(3) equivalent to 0.04(sic)/m(3). The investigation of BEF process proposes a highly cost-effective wastewater treatment method if compared to Actiflo TM and electrocoagulation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:968 / 980
页数:13
相关论文
共 25 条
[1]  
[Anonymous], 2012, ENT PROT GIARD CRYPT
[2]   Electrochemical treatment of cigarette industry wastewater: feasibility study [J].
Bejankiwar, RS .
WATER RESEARCH, 2002, 36 (17) :4386-4390
[3]   Micropollutants in stormwater runoff and combined sewer overflow in the Copenhagen area, Denmark [J].
Birch, H. ;
Mikkelsen, P. S. ;
Jensen, J. K. ;
Lutzhoft, H. -C. Holten .
WATER SCIENCE AND TECHNOLOGY, 2011, 64 (02) :485-493
[4]  
Brahmi K., 2014, DESALIN WATER TREAT, V2014, P1
[5]  
Brahmi K., 2015, ARAB J CHEM
[6]  
Brahmi K, 2016, MINE WATER ENVIRON, V35, P310, DOI 10.1007/s10230-015-0354-4
[7]   Investigation on the electrolysis voltage of electrocoagulation [J].
Chen, XM ;
Chen, GH ;
Yue, PL .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (13) :2449-2455
[8]   Laboratory study of ballasted flocculation [J].
Desjardins, C ;
Koudjonou, B ;
Desjardins, R .
WATER RESEARCH, 2002, 36 (03) :744-754
[9]   Application of response surface methodology to optimize the process variables for fluoride ion removal using maghemite nanoparticles [J].
Fakhri, Ali .
JOURNAL OF SAUDI CHEMICAL SOCIETY, 2014, 18 (04) :340-347
[10]  
Gaid K., 2011, L'Eau, l'Industrie, les Nuisances, P83