Non-Intrusive Data Monitoring and Analysis of Occupant Energy-Use Behaviors in Shared Office Spaces

被引:7
作者
Annaqeeb, Masab Khalid [1 ]
Markovic, Romana [2 ]
Novakovic, Vojislav [1 ]
Azar, Elie [3 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Energy & Proc Engn, N-7491 Trondheim, Norway
[2] Rhein Westfal TH Aachen, E3D Inst Energy Efficiency & Sustainable Bldg, D-52074 Aachen, Germany
[3] Khalifa Univ Sci & Technol, Dept Ind & Syst Engn, Abu Dhabi 127788, U Arab Emirates
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Buildings; energy conservation; monitoring; occupant behavior; performance analysis; shared office; BUILDINGS; PLUG; CONSUMPTION; EQUIPMENT; CONSERVATION; FRAMEWORK; PATTERNS; SYSTEMS; SAVINGS; IMPACT;
D O I
10.1109/ACCESS.2020.3012905
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A non-intrusive data collection framework is developed to analyze the desk-level occupancy and energy use patterns of occupants in shared office spaces. The framework addresses the limitations of previous studies in the literature, which either lacked the granularity to study individual occupants' behaviors or relied on data from complex Building Management Systems (BMS). The framework is applied to a shared office space of an academic institution in the United Arab Emirates (UAE), where occupancy, lighting, and plug-load data were collected from individual desks for 6 months. The results highlight weak relationships between the occupancy status and the total electric loads, with 35% of the total electric loads consumed when the area is completely vacant, and 64% of the plug-load energy consumed when the desks were reported as unoccupied. While specific to the studied building, the results highlight the role that a high-resolution data monitoring framework plays in capturing inefficient consumption patterns. The findings also confirm the contribution of occupant behavior (OB) to the energy performance gap commonly observed between predicted and actual energy levels.
引用
收藏
页码:141246 / 141257
页数:12
相关论文
共 44 条
  • [1] Agarwal Y., 2010, P 2 ACM WORKSH EMB S, P1
  • [2] Energy saving estimation for plug and lighting load using occupancy analysis
    Anand, Prashant
    Cheong, David
    Sekhar, Chandra
    Santamouris, Mattheos
    Kondepudi, Sekhar
    [J]. RENEWABLE ENERGY, 2019, 143 : 1143 - 1161
  • [3] An applied framework to evaluate the impact of indoor office environmental factors on occupants' comfort and working conditions
    Andargie, Maedot S.
    Azar, Elie
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 46
  • [4] [Anonymous], 2019, HOM PAG OCC IOT
  • [5] [Anonymous], 2015, POPULATION PYRAMIDS
  • [6] [Anonymous], 2016, J COMPUT CIVIL ENG, DOI DOI 10.1061/(ASCE)CP.1943-5487.0000507
  • [7] [Anonymous], 2016, ENERG BUILDINGS, DOI DOI 10.1016/J.ENBUILD.2016.04.057
  • [8] [Anonymous], 2019, P 2019 INT C INT, DOI DOI 10.1145/3302505.3310077
  • [9] [Anonymous], 2012, SOC INFLUENCE, DOI DOI 10.1080/15534510.2011.640198
  • [10] Non-intrusive occupancy monitoring for energy conservation in commercial buildings
    Ardakanian, Omid
    Bhattacharya, Arka
    Culler, David
    [J]. ENERGY AND BUILDINGS, 2018, 179 : 311 - 323